• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

三种不同抗凝方法采血动脉血气检测结果的对比分析

Contrast analysis of three anticoagulant methods for arterial blood gas tests

摘要:

目的:比较无抗凝、肝素钠100 IU/ml氯化钠溶液抗凝、固态肝素锂抗凝采集同一患者同一部位动脉血标本行血气分析检测的结果。方法选取ICU需要行动脉血气检测的150例患者作为研究对象,采用3种不同的采血器采集动脉血标本行血气分析,检测血液pH、PaCO2、PaO2、HCT、Hb、BE、HCO3-、Na+、K+、Ca2+、Lac。结果100例全麻大手术后患者用3种不同抗凝采血器采集的动脉血标本检测的pH、PaCO2、PaO2、HCT、Hb、BE、HCO3-、Na+、K+、Ca2+、Lac结果比较,差异无统计学意义( F值分别为0.150,0.298,0.052,0.193,0.163,0.364,0.375,0.874,0.205,2.313,0.059;P>0.05)。50例危重症患者用3种不同抗凝采血器采集的动脉血标本检测的pH、PaCO2、PaO2、HCT、Hb、BE、HCO3-、Na+、K+、Ca2+、Lac结果比较,差异无统计学意义( F 值分别为0.007,0.014,0.023,0.006,0.003,0.008,0.009,0.150,0.023,0.012,0.002;P>0.05)。所有检测项目ICC值最低为0.946,最高为0.999,95%可信区间为0.896~0.999。结论无抗凝、肝素钠100 IU/ml氯化钠溶液抗凝、固态肝素锂抗凝3种方法均适用于采集动脉血标本行血气分析检测。

更多
abstracts:

Objective To compare the testing results of blood gas analysis collected from the same patients with the same blood sampling sites , by no anticoagulant , heparin sodium (100 IU/ml normal saline)and solid lithium heparin .Methods Randomly collected samples from 150 ICU patients by three different hemostix to implement arterial blood gas tests , detected the blood pH , PaCO2 , PaO2 , HCT, Hb, BE, HCO3-,Na+,K+, Ca2+,Lac.Results The test results of arterial blood specimens ( pH, PaCO2 , PaO2 , HCT, Hb, BE, HCO3-, Na+,K+,Ca2+,Lac) of 100 general anesthesia surgery patients in three groups were compared .There were no statistically significant differences between the test results ( F=0.150,0.298,0.052,0.193,0.163,0.364, 0.375,0.874,0.205,2.313,0.059, respectively; P>0.05).The test results of arterial blood specimens of 50 critical patients showed no significant differences ( F=0.007,0.014,0.023,0.006,0.003,0.008,0.009, 0.150,0.023,0.012,0.002, respectively;P>0.05).The lowest and the highest value of ICC were 0.946 and 0.999, with 95%CI (confidence interval) 0.896-0.999 (P>0.05).Conclusions The test results by three different anticoagulant methods show no statistically significant difference .Three methods are suitable for arterial blood samples to apply blood gas analysis .

More
  • 浏览:400
  • 下载:156

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷