Clinical study of domestic ZQL-type retrievable vena cava filter

摘要:

Background Pulmonary thromboembolism (PTE) is a serious disease often leading to disability and death. Percutaneous placement of an inferior vena cava (IVC) filter is an effective method to prevent fatal PTE caused by lower extremity deep venous thrombosis (LEDVT). We developed the ZQL-type retrievable vena cava filter. The aim of this study was to evaluate the safety and effectiveness of the ZQL-type filter for prevention of fatal PTE. Methods A total of 144 patients with indications for placement of an IVC filter received insertion of filters via a femoral (n=37) or jugular (n=107) vein approach. Abdominal X-ray and color Doppler ultrasonography of IVC were regularly performed to visualize the position and condition of the IVC filter following filter placement. If thrombi in the lower extremity deep veins were removed within 2 weeks, the filter retrieval procedure was performed after an abdominal radiograph, an inferior vena cavogram and a pulmonary angiography. Otherwise, the filter should be kept permanently in place with regular follow-up inspections. Results One hundred and forty-four filters were implanted at the target sites with a success rate of 98.61% for one-time placement and 100% for two-time placement. Of the 137 patients followed up (follow-up rate, 95.14%), 43 patients had filters retrieved during a period of between 7 and 14 days (median, 12 days) following filter placement. The remaining 94 patients were followed for 7 days to 39 months (median follow-up period, 17 months). No filter migration or tilt, filter fracture or IVC perforation was observed. No obstruction of IVC occurred. No symptomatic PTE developed during the follow-up period. Conclusion The ZQL-type retrievable vena cava filter is a safe and effective device to prevent PTE. This filter possesses a distinctive stent-shape, stable design, high capture efficacy, and is easy to insert and retrieve and thus is suitable for clinical application.

更多
期刊: 《中华医学杂志(英文版)》2009年122卷2期 140-144页 SCIMEDLINEISTICCSCDBP
分类号: R5
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/cma.j.issn.0366-6999.2009.02.005
发布时间: 2009-03-31
基金项目:
National Science and Technology Research Program in The 9th Five-Year Plan Liaoning Province Science and Technolgoy Commission
翻译满意度评价:
提交
  • 浏览:93
  • 下载:4

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷