• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Assessing validation of dual fluoroscopic image matching method for measurement of in vivo spine kinematics

摘要:

Background Accurate knowledge of the spinal structural functions is critical to understand the biomechanical factors that affect spinal pathology. Many studies have investigated the human vertebral motion both in vitro and in vivo.However, determination of in vivo motion of the vertebrae under physiologic loading conditions remains a challenge in biomedical engineering because of the limitations of current technology and the complicated anatomy of the spine.Methods For in vitro validation, a human lumbar specimen was imbedded with steel beads and moved to a known distance by an universal testing machine (UTM). The dual fluoroscopic system was used to capture the spine motion and reproduce the moving distance. For in vivo validation, a living subject moved the spine in various positions while bearing weight. The fluoroscopes were used to reproduce the in vivo spine positions 5 times. The standard deviations in translation and orientation of the five measurements were used to evaluate the repeatability of technique. The accuracy of vertebral outline matching with metallic marks matching technology was compared.Results The translation positions of the human lumbar specimen could be determined with a mean accuracy less than 0.35 mm and a mean repeatability 0.36 mm for the image matching technique. The repeatability of the method in reproducing in vivo human spine six degrees of freedom (6DOF) kinematics was less than 0.43 mm in translation and less than 0.65° in rotation. The accuracy of metallic marks and vertebral outline matching did not show significant difference.Conclusions Combining a dual fluoroscopic and computerized tomography imaging technique was accurate and reproduceable for noninvasive measurement of spine vertebral motion. The vertebral outline matching technique could be a useful technique for matching of vertebral positions and orientations which can evaluate and improve the efficacy of the various surgical treatments.

更多
期刊: 《中华医学杂志(英文版)》2011年124卷11期 1689-1694页 SCIMEDLINEISTICCSCDBP
分类号: TP391.9
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/CMA.J.ISSN.0366-6999.2011.11.016
发布时间: 2011-07-08
翻译满意度评价:
提交
  • 浏览:202
  • 下载:4

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷