• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Biomechanical properties of peripheral nerve after acellular treatment

摘要:

Background Peripheral nerve injury causes a high rate of disability and a huge economic burden,and is currently one of the serious health problems in the world.The use of nerve grafts plays a vital role in repairing nerve defects.Acellular nerve grafts have been widely used in many experimental models as a peripheral nerve substitute.The purpose of this study was to test the biomechanical properties of acellular nerve grafts.Methods Thirty-four fresh sciatic nerves were obtained from 17 adult male Wistar rats (age of 3 months) and randomly assigned to 3 groups:normal control group,nerve segments underwent no treatment and were put in phosphate buffered saline (pH 7.4) and stored at 4℃ until further use; physical method group,nerve segments were frozen at -196℃ and then thawed at 37℃; and chemical method group,nerve segments were chemically extracted with the detergents Triton X-200,sulfobetaine-10 (SB-10) and sulfobetaine-16 (SB-16).After the acellularization process was completed,the structural changes of in the sciatic nerves in each group were observed by hematoxylin-eosin staining and field emission scanning electron microscopy,then biomechanical properties were tested using a mechanical apparatus (Endura TEC ELF 3200,Bose,Boston,USA).Results Hematoxylin-eosin staining and field emission scanning electron microscopy demonstrated that the effects of acellularization,demyelination,and integrity of nerve fiber tube of the chemical method were better than that of the physical method.Biomechanical testing showed that peripheral nerve grafts treated with the chemical method resulted in some decreased biomechanical properties (ultimate load,ultimate stress,ultimate strain,and mechanical work to fracture) compared with normal control nerves,but the differences were not statistically significant (P >0.05).Conclusion Nerve treated with the chemical method may be more appropriate for use in implantation than nerve treated with the physical method.

更多
期刊: 《中华医学杂志(英文版)》2011年124卷23期 3925-3929页 SCIMEDLINEISTICCSCDBP
分类号: R1
栏目名称: ORIGINAL ARTICLE
DOI: 10.3760/cma.j.issn.0366-6999.2011.23.017
发布时间: 2012-01-12
基金项目:
the National Natural Science Foundation of China the Research Program of Applied Foundation and Advanced Technology of Tianjin
翻译满意度评价:
提交
  • 浏览:194
  • 下载:4

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷