Effect of refractive correction on ocular optical quality measurement using double-pass system

摘要:

Background Optical Quality Analysis System Ⅱ (OQAS,Visiometrics,Terrassa,Spain) that uses double-pass (DP) technique is the only commercially available device that allows objective measurement of ocular retinal image quality.This study aimed to evaluate the impact of spectacle lenses on the ocular optical quality parameters and the validity of the optometer within OQAS.Methods Seventy eyes of healthy volunteers were enrolled.Optical quality measurements were performed using OQAS with an artificial pupil diameter of 4.0 mm.Three consecutive measurements were obtained from spectacle correction corresponding to subjective refraction and from the OQAS built-in optometer separately.The modulation transfer function cutoff frequency,the Strehl ratio,the width of the point spread function (PSF) at 10% of its maximal height (PSF10),and the width of the PSF at 50% of its maximal height (PSF50) were analyzed.Results There was no significant difference in any of the parameters between the spectacle correction and the optometer correction (all P >0.05,paired t-test).A good agreement was found between both the methods and a good intraobserver repeatability in both the correction methods.Difference in best focus between two methods was the only parameter associated significantly with optical quality parameter differences.Best focus difference,built-in optometer correction with or without external cylindrical lens,and age were associated significantly with PSF10 difference.No linear correlation between refractive status and optical quality measurement difference was observed.A hyperopic bias (best focus difference of (0.50±0.44) D) and a relatively better optical quality using spectacle correction in high myopia group were found.Conclusions OQAS based on DP system is a clinically reliable instrument.In patients with high myopia,measurements using built-in optometer correction should be considered and interpreted with caution.

更多
作者单位: Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730; Beijing Ophthalmology & Visual Science Key Laboratory ,Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [1] Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730; Beijing Ophthalmology & Visual Science Key Laboratory ,Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China [2] Department of Ophthalmology and Visual Sciences, Chinese University of Hong Kong, Hong Kong, China [3]
期刊: 《中华医学杂志(英文版)》2013年126卷22期 4289-4294页 SCIMEDLINEISTICCSCDBP
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/cma.j.issn.0366-6999.20130860
发布时间: 2014-01-08
基金项目:
This study was supported by a grant from The Health and Public Welfare Industry Research Program of the Ministry of Health of China
翻译满意度评价:
提交
  • 浏览:152
  • 下载:36

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷