A low-pass filter of 300 Hz improved the detection of pacemaker spike on remote and bedside electrocardiogram

摘要:

Background:The current upper-frequency cutoff of 150Hz sometimes causes loss of pacemaker spike and misdiagnosis.We hypothesized that low-pass filter (LPF) other than 150Hz could improve the detection of pacemaker spike.This study aimed to examine the effect of different LPF on pacemaker spike detection in remote and bedside electrocardiogram (ECG).Methods:Patients with permanent pacemaker implantation were included during routine follow-up.Standard 12-lead ECGs at 6 different upper-frequency cutoff (40,100,150,200,300,and 400 Hz) were collected.All ECGs were then transmitted to the remote clinic center.Ventricular and atrial pacing were analyzed by 2 independent medical practitioners.Results:A total of 88 patients' ECGs were analyzed (mean age 73.8 ±10.2 years and 85 with dual-chamber pacemakers).About 75.3% (64/85) of patients were diagnosed as atrial pacing by pacemaker programming.Among 6 different upper-frequency cutoff,the 300 Hz turned out to perform best in detecting atrial-paced spike (area under the curve [AUC] =0.73,95% confidence interval [CI]:0.61-0.84 vs.0.56,95% CI:0.61-0.84 at 150 Hz;P =0.002) on bedside ECGs.Using programming as the golden standard,the 300Hz LPF has a sensitivity of 59.4%,specificity of 85.7%,positive predictive value of 92.7% and negative predictive value of 40.9% on bedside ECGs.As for the ventricular pacing,the 300Hz LPF also had a higher accuracy (AUC=0.93;95% CI=0.84-1.00) than that at 150 Hz (AUC =0.86;95% CI:0.77-0.94;P < 0.001) in detecting ventricular-paced spike on bedside ECGs.The results of remote ECGs were similar with bedside ECGs.Conclusions:A filter of 300 Hz cutoff may be recommended for ECG spike detection.With the recommended parameter,remote ECG can perform as well as bedside ECG.

更多
作者单位: Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China [1]
期刊: 《中华医学杂志(英文版)》2019年132卷5期 534-541页 SCIMEDLINEISTICCSCDBP
栏目名称: Original Articles
DOI: 10.1097/CM9.0000000000000110
发布时间: 2019-04-16
基金项目:
the project of Shanghai Municipal Education Commission the State Key Program of National Natural Science Foundation of China Shanghai Municipal Commission of Health and Family Planning Funding for Clinical Trial of Xinhua Hospital Shanghai Jiao Tong University School of Medicine grant
翻译满意度评价:
提交
  • 浏览:11
  • 下载:4

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷