医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

不同数量和空间构型的空心拉力螺钉治疗股骨颈骨折的有限元分析

Three-dimensional finite element analysis of different quantity and configuration of cannulated lag screws for femoral neck fractures

摘要目的 探讨4种不同数量和空间构型的空心拉力螺钉治疗股骨颈骨折的生物力学差异. 方法 利用1名65岁健康男性志愿者右股骨颈近端DICOM格式的CT图像,通过三维虚拟软件建立Pauwels Ⅰ、Ⅱ、Ⅲ型股骨颈骨折模型和4种不同数量及构型的内固定模型(3钉正三角形、3钉倒三角形、4钉矩形、4钉菱形).将模型导入有限元分析软件Ansys软件中,模拟直立情况下内固定及骨折区域的位移及应力分布情况.观测内固定物应力峰值、头侧骨折断端应力峰值和股骨头处位移峰值. 结果 对于4种不同数量及正三角形、倒三角形、矩形、菱形构型的内固定模型,在Pauwels Ⅰ型骨折时,应力峰值分别为46.382,32.159,43.985,24.342 MPa;头侧股骨颈骨折断端应力峰值分别为5.840,7.440,3.731,6.311MPa;股骨头处位移峰值分别为0.610,0.608,0.598,0.595 mm.在PauwelsⅡ型骨折时,应力峰值分别为46.763,39.979,49.619,25.692 MPa;头侧股骨颈骨折断端应力峰值分别为4.971,7.332,3.161,5.734 MPa;股骨头处位移峰值分别为0.634,0.635,0.622,0.631 mm.在PauwelsⅢ型骨折时,应力峰值分别为51.432,39.477,51.515,26.949 MPa;头侧股骨颈骨折断端应力峰值分别为6.163,10.070,5.257,9.552 MPa;股骨头处位移峰值分别为0.662,0.654,0.644,0.644 mm. 结论 4枚菱形排列的空心拉力螺钉固定股骨颈骨折具有更优的应力分散作用,能够使骨折断端更加稳定且能提供有效的滑动加压作用和抗扭力作用,具有更佳的生物力学优势,从而指导临床应用.

更多

abstractsObjective To analyze biomechanical differences among quantity configurations of four common cannulated screws using three-dimensional finite element analysis.Methods The Dicom CT images of the right proximal femoral neck of a 65-year-old Chinese healthy volunteer were used to establish models of three kinds of different Pauwels types of femoral neck and four kinds of different quantity and configuration models (triangle,inverted triangle,rectangle,diamond) through three-dimensional virtual softwares.Models were imported into the finite element analysis software Ansys.After axial load application,the stress and displacement on the screws and femoral head were compared.The peak stresses on the screws,peak stresses on the femoral head break side and displacement peaks were observed.Results Four kinds of quantity and configuration models (triangle,inverted triangle,rectangle,rhombus) had different peak stress on the screws and femoral head break side and different displacement peak.Among Pauwels type Ⅰ fractures,the peak stresses on the screws were 46.382,32.159,43.985,and 24.342 MPa;the peak stresses on the femoral head break side were 5.840,7.440,3.731,and 6.311 MPa;the displacement peaks were 0.610,0.608,0.598,and 0.595 mm.Among Pauwels type Ⅱ fractures,the peak stresses on the screws were 46.763,39.979,49.619,and 25.692 MPa;the peak stresses on the femoral head break side were 4.971,7.332,3.161,and 5.734 MPa;the displacement peaks were 0.634,0.635,0.622,and 0.631 mm.Among Pauwels type Ⅲ fractures,the peak stresses on the screws were 51.432,39.477,51.515,and 26.949 MPa,and the peak stresses on the femoral head break side were 6.163,10.070,5.257,and 9.552 Mpa;the displacement peaks were 0.662,0.654,0.644,and 0.644 mm.Conclusion The fixation of femoral neck fractures with four screws in a diamond position can guide clinical application,for the procedure has better stress dispersion effects,ensure fracture stablility,provide effective sliding compression and anti-torsion and have biomechanical advantages.

More
广告
  • 浏览455
  • 下载262
中华创伤杂志

中华创伤杂志

2017年33卷9期

815-822页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷