脉搏血氧仪筛查先天性心脏病的有效性研究

Effectiveness of pulse oximetry for the screening of congenital heart disease in newborn infants

摘要:

目的 探讨脉搏血氧仪筛查先天性心脏病的效果.方法 选择2010年1月至2013年12月在我院新生儿科住院且无紫绀的足月新生儿,随机分为脉搏血氧仪组和体格检查组.脉搏血氧仪组应用脉搏血氧仪测量肢体的脉搏血氧饱和度筛查先天性心脏病,体格检查组由医生行心脏听诊筛查先天性心脏病.计算两组筛查的敏感度、特异度、阳性预测值和阴性预测值,记录筛查结果为假阴性的新生儿需行手术治疗的例数.结果 脉搏血氧仪组完成随访4 277例,确诊先天性心脏病514例,其中筛查阳性407例,假阴性107例;体格检查组完成随访3 827例,确诊先天性心脏病663例,其中筛查阳性299例,假阴性364例.单纯房间隔缺损、房间隔缺损+动脉导管未闭、单纯动脉导管未闭脉搏血氧仪组筛查阳性率高于体格检查组,差异有统计学意义(P<0.05).脉搏血氧仪组敏感度79.2%,特异度85.6%,阳性预测值42.9%,阴性预测值96.8%.体格检查组敏感度45.1%,特异度83.2%,阳性预测值35.9%,阴性预测值87.8%.两组筛查结果为假阴性的新生儿需行手术治疗的比例差异无统计学意义(2/107比4/364,P>0.05).结论 应用脉搏血氧仪筛查先天性心脏病简单方便、准确性高.

更多
abstracts:

Objective To investigate the effectiveness of pulse oximetry for the screening of congenital heart disease.Methods From 2010.01 to 2013.12,newborn infants without cyanosis from the Neonatal Department of Zhongshan People's Hospital were randomly divided into two groups:Pulse Oximetry (PO) group and Clinical Examination (CE) group.In the PO group,congenital heart disease was screened by measuring the SpO2 with pulse oximetry.In the CE group,congenital heart disease was screened by clinical examination.The sensitivity,specificity,positive predictive value and negative predictive value were calculated in both groups.The corrective surgery rate in newborns infants,which were screened as false negative,was recorded in both groups.Results In the PO group,4 277 patients were followed over time,514 infants were diagnosed as having congenital heart disease,407 infants were screened as positive,and 107 infants had false negative screening.In the CE group,3 827 patients were followed over time,663 infants were diagnosed as having congenital heart disease,299 infants were screened as positive,and 364 infants had false negative screening.The positive screening rate was higher in the PO group than in the CE group for the infants with atrial septal defect only,atrial septal defect + patent ductus arteriosus,and patent ductus arteriosus only (P < 0.05).In the PO group,the sensitivity,specificity,positiv predictive value and negative predictive value were 79.2%,85.6%,42.9% and 96.8% respectively.In the CE group,the sensitivity,specificity,positive predictive value and negative predictive value were 45.1%,83.2%,35.9% and 87.8% respectively.Corrected surgery rate in newborn infants with false negative result was similar between the two groups (2/107 vs.4/364,P >0.05).Conclusions Pulse oximetry screening is simple,convenient and effective for detecting congenital heart disease in newborn infants.

More
  • 浏览:508
  • 下载:177

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷