医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

停戴角膜塑形镜后屈光度及角膜屈光力回退的临床观察

Regression of refractive error and corneal curvature after discontinuation of orthokeratology lens wear

摘要目的 观察短期停戴角膜塑形镜后屈光度及角膜屈光力回退率.方法 自身对照研究.36例(69眼)患者配戴角膜塑形镜3个月效果稳定,复查时在摘镜后即时、摘镜10 h、摘镜24h观察停戴镜片后的改变.观察指标包括裸眼视力、主观验光、角膜地形图检查.根据已被矫正的屈光度分为3组:>-4.50 D组,-3.12~-4.50 D组,-0.12~-3.00 D组.采用描述性统计方法.结果 摘镜后不同时间点各参数均逐渐回退.摘镜10 h及摘镜24 h,裸眼视力(logMAR)分别回退0.09±0.20(回退率为11%)和0.30±0.24(回退率为36%).等效球镜度分别回退(0.25±0.74)D(回退率为8%)和(1.15±1.05)D(回退率为36%),角膜平均屈光力(simK)分别回退(0.00±0.85)D(回退率0%)和(0.62±0.68)D(回退率为46%).不同组别回退速度不同,配戴前屈光度越高,停戴后回退的速度越快.结论 摘镜后白天10 h屈光度及角膜屈光力可保持相对稳定,停戴24 h后回退明显,且配戴前屈光度越高,回退的速度越快.

更多

abstractsObjective To describe the regression of refraction and corneal curvature shortly after discontinuing orthokeratology lens wear.Methods This was a self-controlled study.Thirty-six patients (69 eyes) were assessed after wearing orthokeratology lenses for 3 months.Refractive error,uncorrected visual acuity (UCVA) and corneal topography were measured within zero hour after waking and at 10 and 24 hours.Comparison of regression was analyzed for the three levels of myopia achieved (>-4.50 D,-3.12~-4.50 D,-0.12~-3.00 D).Descriptive statistics were used in this study.Results In general,all the parameters returned toward the baseline after discontinuation of lens wear.At 10 and 24 hours,UCVA (logMAR) returned to 0.09±0.20 (regression rate 11%) and 0.30±0.24 (regression rate 36%),respectively.Spherical equivalent refraction returned to 0.25±0.74 D (regression rate 8%) and 1.15±1.05 D (regression rate 36%),respectively.Corneal curvature (simK) returned to 0.00±0.85 D (recovery rate 0%) and 0.62±0.68 D (recovery rate 46%).The greater the magnitude of refractive error,the more quickly it returned to baseline.Conclusion Refractive error and corneal curvature were relatively stable for 10 hours after discontinuation of orthokeratology lens wear,but all parameters returned and trended to baseline 24 hours after discontinuation.The greater the refractive error,the more quickly it returned to baseline.

More
广告
栏目名称
DOI 10.3760/cma.j.issn.1674-845X.2014.02.004
发布时间 2014-04-22(万方平台首次上网日期,不代表论文的发表时间)
基金项目
国家自然科学基金(81200716); 广东省自然科学基金(S2012010008634)
  • 浏览902
  • 下载304
中华眼视光学与视觉科学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷