• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

ELISA法和LABScreen法检测HLA抗体结果的差异

The difference of ELISA and LABScreen in detecting HLA antibodies

摘要:

目的 比较ELISA法和LABScreen法检测HLA抗体结果的差异性,并分析两者对移植肾排斥的影响.方法 选取2008年11月至2009年12月期间在本科做肾移植和随访发现肌酐异常并且有肾穿记录怀疑移植肾排斥或者临界改变的患者,用莱姆德抗原板(LAT)和混合抗原板(LAT-MIX)通过ELISA方法检测HLA抗体,并与LABScreen技术检测的HLA抗体结果比较,研究两种方法对肾移植排斥检测结果的差异.结果 共277例患者被纳入研究,其中新移植230例,随访47例,术前HLA抗体阳性病例ELISA法为27例(9.7%),LABScreen法为145例(52.3%).其中ELISA法阴性而LABScreen法阳性的病例为118例(42.6%),ELISA法阳性的病例LABScreen法均阳性.未出现LABScreen法阴性而ELISA法阳性的病例,LABScreen法阳性而ELISA阴性的118个病例中,术后出现移植肾排斥的病例为41例(34.7%).两者均阴性的132个病例中,出现术后移植肾排斥的病例为24例(18.2%)(P=0.003).排斥组术后两周HLA抗体荧光强度不低于术前的占31%,而在非排斥组,术后两周HLA抗体荧光强度不低于术前的比例仅占12.8% (P< 0.01).结论 LABScreen法在对HLA抗体检出率及敏感性上远高于ELISA法,并与移植肾排斥密切相关.

更多
abstracts:

Objective To compare the difference of ELISA and LABScreen in detecting HLA antibodies and evaluate their effects on allograft rejection.Methods Consecutive patients undergoing kidney transplantion from November,2008 to December,2009 in the First Affiliated Hospital and the following up patients during the same period,with abnormal Scr who had completed kidney biopsies,were included in this study.Patients' HLA antibodies were detected by ELISA (Lambda antigen tray,LATTM) and LABScreen Mix Beads (LABScreen MIX,One Lambda,Canoga Park,CA,USA) or LABScreen Single antigen beads (LABScreenTM single antigen beads,One Lambda,Canoga Park,CA,USA).Patients' Scr were also detected at different time potints.Results There were 277 patietns included.Among them 145 (52.3%) cases were HLA antibody positive detected by LABScreen,which including 118 cases ELISA negative but LABScreen positive,and 27 cases both ELISA and LABScreen positive.No case was ELISA positive but LABScreen negative.Among 118 cases which were LABScreen positive but ELISA negative,41 (34.7%) cases happened acute or chronic rejection.However,only 24 cases happened rejection in 132 double negative cases (18.2%,P =0.003).There were 31% patients in rejection group while only 12.8% patients (P=0.01) in non-rejection group whose HLA antibody fluorescence intensity detected by LABScreen single antigen beads still increased two weeks after transplantation.Conclusion LABScreen is more sensitive than ELISA in detecting HLA antibodies,and its result highly correlates with the incidence of allograft rejection.

More
作者: 吴萍萍 [1] 金娟 [1] 王宇成 [1] 王霞月 [1] 陈江华 [1]
期刊: 《中华肾脏病杂志》2013年29卷5期 321-325页 ISTICPKUCSCD
栏目名称: 临床研究
DOI: 10.3760/cma.j.issn.1001-7097.2013.05.001
发布时间: 2013-07-24
基金项目:
省科技厅重大专项
  • 浏览:516
  • 下载:60

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷