• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

多层螺旋CT诊断冠状动脉狭窄的价值和限度

Value and limitations of multislice spiral CT in diagnosing coronary artery stenoses

摘要:

目的 评价多层螺旋CT(MSCT)在冠状动脉狭窄诊断中的价值和限度.方法 临床诊断或可疑冠心病的65例患者接受冠状动脉MSCT检查,采用回顾性心电门控、0.5 s/转的螺旋扫描、单扇区重建算法和静脉注射对比剂,其检查结果与导管法,冠状动脉造影进行对照.结果 在65例患者的冠状动脉889节段(直径≥1.5 mm)中,CT图像满足管腔评价为795节段(占89.4%).对于CT图像满足管腔评价的冠状动脉节段,MSCT对冠状动脉中度和中度以上狭窄(≥50%)诊断的敏感度和特异度分别为88.6%和95.1%,阳性预测值和阴性预测值分别为82.7%和96.9%;MSCT显示冠状动脉高度狭窄(≥75%)的敏感度和特异度分别为90.7%和97.6%,阳性预测值和阴性预测值分别为82.1%和98.9%.结论 如果冠状动脉CT图像满足管腔评价,MSCT对冠状动脉狭窄的诊断准确性很高.MSCT可用于冠状动脉狭窄的初步诊断和介入治疗的筛选.

更多
abstracts:

Objective To evaluate the value and limitations of muhislice spiral CT in diagnosing coronary artery stenoses.Methods A total of 65 patients with known or suspected coronary artery disease were examined by muhislice spiral CT (retrospectively ECG-gating;0.5 s rotation;one-sector reconstruction algorithm;intravenous contrast agent) and the results were compared with quantitative coronary angiography.Results In the 889 coronary artery segments of 65 patients,795 could be evaluated by CT (89.4%),148 out of 167 coronary artery segments with significant stenoses (≥50%reduction of vessel diameter) were correctly detected by CT,597 out of 628 coronary artery segments with normal or mild stenosis (<50% reduction of vessel diameter) were correctly detected by CT.These values correspond to a sensitivity of 88.6%,specificity of 95.1%,positive predictive value of 82.7%,and negative predictive value of 96.9% for the detection of significant coronary artery stenosis by CT.Adding the 23 coronary artery segments with significant stenosis which could not be judged by CT,the sensitivity of CT for diagnosing coronary stenosis was 77.9%.In the 795 evaluable coronary artery segments,78 out of 86 coronary artery segments with high-grade stenosis (≥75% reduction of vessel diameter) were correctly detected by CT,692 of 709 coronary artery segments with normal or mild stenosed (<75% reduction of vessel diameter) were correctly detected by CT.These values correspond to a sensitivity of 90.7%,specificity of 97.6%,positive predictive value of 82.1%,and negative predictive value of 98.9% for the detection of high-grade coronary artery segments stenosis by CT.Adding 13 coronary artery segments with high-grade stenosis which could not be judged by CT,the sensitivity was 78.8%.Conclusion Muhislice spiral CT permits the visualization of significant coronary artery stenosis with high accuracy in cage of sufficient image quality.

More
  • 浏览:458
  • 下载:308

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷