ICL植入术后早期非计划再次手术临床分析

Clinical Analysis of Unplanned Reoperation Following Implantable Collamer Lens Implantation in the Early Post-Operative Period

摘要目的::评估有晶状体眼人工晶状体(ICL)植入手术患者术后早期非计划再次手术率及再次手术的原因、处理方法及转归。方法::回顾性临床研究。选择2020年4月至2021年3月在北京协和医院眼科行ICL植入手术的患者744例(1483眼),对其中行非计划再次手术的患者进行手术原因及处理方法分析。将因拱高异常进行非计划再次手术者分为低拱高组和高拱高组。使用Kruskal-Wallis检验比较各组的年龄及屈光度;采用方差分析比较各组白到白距离、房角到房角距离、前房深度、晶状体矢高、晶状体厚度、眼轴及拱高;采用 t检验比较再次手术前后的拱高、散光度数及裸眼视力。 结果::在术后2周内进行非计划再次手术共37眼(2.49%)。其中进行ICL调位术34眼,ICL置换术3眼。最常见的再次手术原因为拱高异常和散光残留。进行ICL调位术的原因为高拱高(13眼)、残留散光(11眼)、低拱高(10眼)。进行ICL置换术的原因为低拱高(2眼)和高拱高(1眼)。通过再次手术,高拱高组的拱高由(974±174)μm降低至(691±120)μm,低拱高组的拱高由(174±49)μm增加至(388±78)μm,散光残留眼的散光由(1.34±0.34)D降至(0.39±0.26)D,手术前后差异均有统计学意义(均 P<0.001)。再次手术无手术并发症出现。 结论::拱高异常和散光残留是ICL植入术后早期进行非计划再次手术的主要原因,通过再次手术均可获得理想拱高和屈光度。

更多

abstractsObjective::To determine the incidence of unplanned reoperation following implantable collamer lens (ICL) implantation in the early postoperative period and analyze the reasons, treatment and prognosis for reoperation.Methods::In this retrospective clinical study, all patients undergoing ICL implantation at Peking Union Medical College Hospital between April 2020 and March 2021 were reviewed. A total of 1483 cases of ICL implantation operations were performed. The reasons, treatment and prognosis for unplanned reoperation were analyzed. The eyes that had unplanned reoperation because of abnormal vault were divided into low vault group and high vault group. Kruskal Wallis test was used to compare the age and diopters of the eyes in each group. Variance analysis was used to compare the white to white distance, angle to angle distance, anterior chamber depth, lens rise, lens thickness, axial length and vault of the eyes in each group. t test was used to compare the vault, astigmatism and uncorrected visual acuity before and after reoperation. Results::Thirty-seven eyes (2.49%) underwent unplanned reoperation within two weeks after the ICL implantaion. Among them, ICL rotation was performed on 34 eyes and ICL exchange on 3 eyes. The most common reasons for reoperation were abnormal vault and residual astigmatism. The reasons for the ICL rotation were high vault (13 eyes), residual astigmatism (11 eyes), and low vault (10 eyes). The reasons for the 3 eyes of ICL exchange were low vault (2 eyes) and high vault (1 eye). After reoperation, the vault of the high vault group was decreased from 974±174 μm to 691±120 μm, the vault of the low vault group was increased from 174±49 μm to 388±78 μm, the astigmatism of the residual astigmatism group was drecreased from 1.34±0.34 D to 0.39±0.26 D, and all the changes were statistically significant ( P<0.001). No complications were encountered during reoperation. Conclusions::Abnormal vault and residual astigmatism were the main reasons for unplanned reoperation. The desired vault and diopter could be achieved through reoperation.

More
广告
栏目名称
DOI 10.3760/cma.j.cn115909-20211227-00504
发布时间 2025-12-28(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览131
  • 下载6
中华眼视光学与视觉科学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷