• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Primary prevention of sudden cardiac death by implantable cardioverter-defibrillator therapy in Chinese patients with heart failure: a single-center experience

摘要Background An implantable cardioverter-defibrillator (ICD) has been suggested for heart failure patients for primary prevention of sudden cardiac death. However, few data have been reported on the application of ICD as primary prevention of sudden cardiac death in China. We evaluated the value of primary prevention ICD therapy in Chinese patients with heart failure.Methods Thirty-four patients at an average age of (60.2±13.7) years seen in Peking Union Medical College Hospital were treated with ICD implantation for primary prevention of sudden cardiac death from November 2005 to July 2009. Single-chamber ICDs were implanted in 16 (47.0%) cases, and dual-chamber or cardiac resynchronization therapy defibrillators in 18 (53.0%) cases. The patients had an average left ventricular ejection fraction of (26.9±5.5)% (11% to 35%), of which 18 (53.0%) patients had ischemic cardiomyopathy and 16 (47.0%) patients had non-ischemic cardiomyopathy. All patients were followed up at three months after the implantation and every six months thereafter or when prompted by an ICD event.Results There were five (14.7%) deaths, including two of heart failure and three with a non-cardiac course, during an average follow-up of (15.0±11.9) months. Forty-one ICD therapy events were recorded, including 19 (46.3%) appropriate ICD therapies in six patients and 22 (53.7%) inappropriate ICD therapies in four patients with single chamber leads. Inappropriate ICD therapies were mainly due to supraventricular tachyarrhythmias, especially atrial fibrillation. Patients with ischemic cardiomyopathy and non-ischemic cardiomyopathy did not differ in the incidence of either appropriate or inappropriate therapy.Conclusions ICD for primary prevention of sudden cardiac death in China prevents patients from arrhythmia death. Relatively high incidence of inappropriate therapies highlights the importance of an atrial lead.

更多
广告
分类号 R5
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2010.07.016
发布时间 2010-06-02
提交
  • 浏览130
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2010年123卷7期

848-851页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷