Comparison of compensatory sweating and quality of life following thoracic sympathetic block for palmar hyperhidrosis: electrocautery hook versus titanium clip

摘要Background Video-assisted thoracic sympathetic block is an effective,safe,and minimally invasive method fortreatment of primary hyperhidrosis.The purpose of this study was to decide which one of using electrocautery hook and titanium clip is the appropriate procedure for primary palmar hyperhidrosis by assessing the compensatory sweating (CS)and quality of life (QOL) of patients after sympathetic block.Methods Between October 2007 to August 2010,120 patients with primary palmar hyperhidrosis were randomly divided into two groups,electrocautery hook group (60 patients) and titanium clip group (60 patients).All patients were treated by sympathetic block at T4 level.The CS was graded based on severity and location; the QOL was classified to 5 different levels based upon the summed total scores (range from 20 to 100) before and after surgery.The variables were compared.Results The postoperative follow-up period was 2 months.All patients were cured.Three patients in electrocautery hook group and 1 patient in titanium clip group had a unilateral pneumothorax on chest X-ray,but none of them was necessary to have chest drainage.Neither perioperative mortality nor serious complications such as cardiac arrhythmia or arrest were observed during the operation.No bradycardia or Horner's syndrome occured.CS was not more common in patients in titanium clip group than in those in electrocautery hook group (P=0.001).Moderate and severe CS was few in all patients,and there was no significant difference between two groups (P=-0.193).Most of the patients feel a notable improvement of the the QOL; nevertheless,there was no significant difference between the groups (P=0.588).Conclusions Both electrocautery hook and titanium clip used for sympathetic block at the T4 level are effective,safe,and minimally invasive for palmar hyperhidrosis.Because of the lower severity of CS and the similar improvements in the QOL after operation,we prefer to use of titanium clip for treating palmar hyperhidrosis.

更多
广告
作者单位 Department of Cardiothoracic Surgery, Second Affiliated Hospital, Soochow University, Suzhou, Jiangsu 215004, China [1]
分类号 R1
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2011.21.011
发布时间 2012-01-12
提交
  • 浏览165
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2011年124卷21期

3495-3498页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷