Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial

摘要Background Computer-assisted procedures have recently been introduced for navigated femoral neck screw placement.Currently there is little information available regarding accuracy and efficiency of the different navigated procedures.The aim of this study was to compare two fluoroscopic navigation tracking technologies,a novel bi-planar robot navigation and standardized optoelectronic navigation,versus standard freehand fluoroscopic insertion in a Synbone hip model.Methods Eighteen fixed Synbone hip models were divided into 3 groups.C-arm navigated cannulated screws (AO-ASIF,diameter 7.3 mm) were inserted using freehand targeting (control group).A novel bi-planar robot system (TINAV,GD2000) and an optoelectronic system (Stryker OTS Navigation System) were used for the navigated procedures (robot group and optoelectronic group).Accuracy was measured using radiographic evaluation including the measurement of screw parallelism and decentralization,and joint penetration.To evaluate the efficiency,the number of guidewire passes,operative time and fluoroscopic images taken were noted.Results The two computer-assisted systems provided significantly improved accuracy compared to the freehand technique.Each of the parameters,including guidewire passes and number of fluoroscopy images,was significantly lower when using the computer-assisted systems than for freehand-unguided insertion (P <0.05),but operative time was significantly shorter when using freehand-unguided insertion than for the computer-assisted systems (P <0.05).Accuracy,operative time and number of fluoroscopy images taken were similar among the two navigated groups (P >0.05),but guidewire passes in the robot group were significantly less than in the optoelectronic group (P <0.05).Conclusions Both bi-planar robot navigation and optoelectronic navigation were similarly accurate and have the potential to improve accuracy and reduce radiation for freehand fluoroscopic targeting for insertion of cannulated screws in femoral neck fractures.Guidewire passes in the robot group were significantly less than in the optoelectronic group.However,both navigated procedures were associated with time-consuming registration and high rates of failed matching procedures.

更多
广告
分类号 R1
栏目名称 ORIGINAL ARTICLE
DOI 10.3760/cma.j.issn.0366-6999.2011.23.014
发布时间 2012-01-12
基金项目
Beijing Municipal Committee of Science and Technology
提交
  • 浏览304
  • 下载24
中华医学杂志(英文版)

中华医学杂志(英文版)

2011年124卷23期

3906-3911页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷