• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia guided by magnetic navigation system: a prospective randomized comparison with conventional procedure

摘要Background Atrioventricular nodal reentrant tachycardia (AVNRT) is one of the most common paroxysmal supraventricular tachyarrhythmias.The aim of the study was to prospectively compare the characteristics of radiofrequency catheter ablation of AVNRT guided by a magnetic navigation system with the conventional procedure.Methods Patients with AVNRT diagnosed by electrophysiological tests were randomized into two groups.In the conventional technique group (CMT),a common 4-mm-tip quadrapolar temperature-controlled ablation catheter was used. In the magnetic navigation system guidance group (MNS), a magnetic 4-mm-tip quadrapolar temperature-controlled ablation catheter was used.The following parameters were collected and compared between the two groups: ablation procedure time,patient fluoroscopy time,operator fluoroscopy time,energy delivery numbers,maximal energy per deployment,success rate,complication rate and operative cost.Results Forty patients were enrolled and randomized into CMT and MNS groups.The age,gender,tachycardia history and basic cardiovascular diseases of the two groups were comparable (P >0.05).All procedures were conducted successfully without complications.No tachycardia recurred during the follow-up period of (9.3±2.6) months.In the MNS group,the patient and operator fluoroscopy times ((11.5±4.3) min,(4.2±1.5) min),energy delivery numbers (3.2±0.9),and maximal energy per deployment ((16.9±3.4) W) were shorter or lower than those of the CMT group ((14.3±6.2) min,(13.6±3.5) min,6.3±2.1,(23.7±1.3) W,respectively) (P <0.05).But the operative cost for the MNS group was higher than that of the CMT group (P <0.01 ).Conclusion Magnetic navigation system guided radiofrequency catheter ablation of AVNRT has the advantages of shorter fluoroscopy time and lower energy delivery numbers and maximal energy per deployment compared to the present conventional ablation technique.

更多
广告
作者单位 Institute of Geriatric Cardiology, Chinese People's Liberation Army General Hospital, Beijing 100853, China [1]
分类号 R541
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.2012.01.004
发布时间 2012-03-20
基金项目
This study was supported by a grant from the Logistics Department of Chinese People's Liberation Army
提交
  • 浏览199
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷