Differentiation of white and red thrombus with magnetic resonance imaging: a phantom study

摘要Background An early identification of the composition of arterial thrombus may have diagnostic,therapeutic,and prognostic implications.The variation of magnetic resonance (MR) signal intensity between white and red thrombi,especially in the susceptibility sensitive MR sequence,remains unknown.Our research was to evaluate the feasibility of MRI in differentiating of white and red thrombi with a phantom study.Methods A total of 12 red and 12 white thrombi were prepared with the venous blood.Examination of the phantom was completed using a 3.0T MR unit,including fluid attenuated inversion recovery (FLAIR) T1,T2-weighted imaging (T2WI),FLAIR T2,T2* gradient echo (T2*GRE) imaging,and susceptibility weighted angiography sequences (SWAN).MR signal intensity patterns of the thrombi were objectively classified as hyperintensity,isointensity and hypointensity,compared with the background agar.The volume of thrombus was calculated and correlated with its signal intensity.Results For white thrombi,11/12 clots showed hyperintensity and 1/12 showed isointensity in FLAIR T1 images.In T2WI,6/12 clots showed hyperintensity,3/12 isointensity,and 3/12 hypointensity.In FLAIR T2,8/12 clots showed hyperintensity and 4/12 showed isointensity.In T2*GRE,3/12 clots showed hyperintensity and the remaining 9/12 clots showed isointensity.In SWAN,5/12 clots demonstrated hyperintensity and 7/12 isointensity.For the red thrombus,12/12 clots demonstrated hyperintensity in FLAIR T1,T2WI,and FLAIR T2 sequences.In T2*GRE and SWAN sequences,3/12 clots displayed hypointensity and the remaining 9/12 clots showed slight hyperintensity.Thrombi with hypointensity displayed in T2*GRE and SWAN sequences were significantly larger than those with hyperintensity.Conclusions Differentiation of white and red thrombi with conventional MR sequence is unreliable,because both kinds of thrombi do not possess unique signal intensity features in these sequences.Red thrombus may or may not show hypointensity in the susceptibility sensitive MR sequences,depending on its size and time course.

更多
广告
分类号 R2
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.2012.11.009
发布时间 2012-08-09
基金项目
the Science and Technology Council of Ningbo,Zhejiang Province
提交
  • 浏览127
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年11期

1889-1892页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷