医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Diffusion tensor imaging-derived measures of fractional anisotropy across the pyramidal tract are influenced by the cerebral hemisphere but not by gender in young healthy volunteers: a split-plot factorial analysis of variance

摘要Background Diffusion tensor imaging (DTI) permits quantitative examination within the pyramidal tract (PT) by measuring fractional anisotropy (FA).To the best of our knowledge,the inter-variability measures of FA along the PT remain unexplained.A clear understanding of these reference values would help radiologists and neuroscientists to understand normality as well as to detect early pathophysiologic changes of brain diseases.The aim of our study was to calculate the variability of the FA at eleven anatomical landmarks along the PT and the influences of gender and cerebral hemisphere in these measurements in a sample of young,healthy volunteers.Methods A retrospective,cross-sectional study was performed in twenty-three right-handed healthy volunteers who underwent magnetic resonance evaluation of the brain.Mean FA values from eleven anatomical landmarks across the PT (at centrum semiovale,corona radiata,posterior limb of internal capsule (PLIC),mesencephalon,pons,and medulla oblongata) were evaluated using split-plot factorial analysis of variance (ANOVA).Results We found a significant interaction effect between anatomical landmark and cerebral hemisphere (F (10,32)=4.516,P=0.001; Wilks' Lambda 0.415,with a large effect size (partial n2=0.585)).The influence of gender end age was non-significant.On average,the midbrain and PLIC FA values were higher than pons and medulla oblongata values; centrum semiovale measurements were higher than those of the corona radiata but lower than PLIC.Conclusions There is a normal variability of FA measurements along PT in healthy individuals,which is influenced by regions of interest location (anatomical landmarks) and cerebral hemisphere.FA measurements should be reported for comparing same-side and same-landmark PT to help avoid comparisons with the contralateral PT; ideally,normative values should exist for a clinically significant age group.A standardized package of selected DTI processing tools would allow DTI processing to be routinely performed in clinical settings.

更多
广告
分类号 R4
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2012.12.018
发布时间 2012-08-31(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览234
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年125卷12期

2180-2187页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷