• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Correlation of eosinophil counts in induced sputum and fractional concentration of exhaled nitric oxide and lung functions in patients with mild to moderate asthma

摘要Background The airway inflammation could be assessed by some noninvasive approaches.To investigate the value of eosinophil counts in induced sputum and fractional concentration of exhaled nitric oxide (FENO) for the regimen adjustment in patients with asthma,the correlation was analyzed between the two parameters and lung function parameter (forced expiratory volume in one second (FEV1)).Methods Sixty-five outpatients with mild to moderate non-exacerbation asthma from Beijing Chao-Yang Hospital were enrolled as treatment group.Combined medications of inhaled corticosteroids plus long-acting beta-2 agonist were administered for one year.Lung function parameters,eosinophil counts in induced sputum,concentration of exhaled nitric oxide and the Asthma Control Test scores were recorded,at regular intervals in the follow-up period.Twenty-one healthy volunteers were enrolled as control group and underwent examination of eosinophil counts in induced sputum,lung function and concentration of exhaled nitric oxide.Results Sixty-three subjects from treatment group completed follow-up period for one year or longer.Mean FEV1 value of the 63 subjects was (2.75±0.54) L at baseline,(2.97±0.56) L and (3.07±0.52) L at month 3 and month 6,respectively,and maintained as (3.14±0.51) L in the following six months.Mean FENO decreased from (61±25) parts per billion (ppb) at baseline to (32±19) ppb at month 3 (P <0.05),and continued to decrease to (22±12) ppb at month 6,the difference being significant when compared to both baseline and control group ((13±8) ppb).Mean eosinophil counts decreased to (0.032±0.011) ×106/ml at month 3,which was significantly different from baseline ((0.093±0.023)×106/ml) and the control group ((0.005±0.003) ×106/ml (both P <0.05).The eosinophil counts in induced sputum correlated positively with concentration of FENO in the first six months (all P <0.05).The concentration of FENO had a significant negative correlation with FEV1 value (all P <0.05) in any time point in the follow-up period.The Asthma Control Test scores were 18±5,19±7,23±2,24±1 and 24±1 at months 1,3,6,9 and 12,respectively,which were significantly different from the score at baseline (14±3) (P <0.05 ).The most rapid clinical effect was observed at the second month after treatment.Conclusion Eosinophil counts in induced sputum and FENO are sensitive parameters to detect airway inflammation and may be useful in evaluating the efficacy of treatment and adjusting medication regimens.

更多
广告
作者单位 Department of Respiratory and Critical Care Medicine,Beijing Chao-Yang Hospital,Capital Medical University & Beijing Institute of Respiratory Medicine,Beijing 100020,China [1]
分类号 TU746.2
栏目名称 BRIEF REPORTS
DOI 10.3760/cma.j.issn.0366-6999.2012.17.034
发布时间 2012-11-16
基金项目
This study was supported by the grants from Beijing Municipal Science and Technology Commission Foundation of R & D Research Chinese Medicine Clinical Research Special Funds Project the Basic-Clinical Cooperation Project in Capital Medical University
提交
  • 浏览197
  • 下载36
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年125卷17期

3157-3160页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷