Comparison of paclitaxal vs.sirolimus eluting stents with bio-degradable polymer for the treatment of coronary bifurcation lesions: subgroup analysis from DKCRUSH-I and DKCRUSH-Ⅱ studies

摘要Background The difference in clinical outcome between paclitaxal-eluting stents (PES) and sirolimus-eluting stents with bio-degradable polymer (SES-BDP) for bifurcation lesions remains unclear.The present study aimed to investigate the one-year clinical outcome after DK crush stenting using PES (TaxusTM) vs.SES-BDP (ExcelrM) from our database.Methods A total of 275 patients (90 from the DKCRUSH-I and 185 from the DKCRUSH-Ⅱ study) were studied.The primary endpoint was the occurrence of major adverse cardiac events (MACE) at 12 months; including cardiac death,myocardial infarction (MI),or target vessel revascularization (TVR).The rate of binary restenosis and stent thrombosis served as secondary endpoints.Results At follow-up,minimal luminal diameter (MLD) in the Taxus group was (2.11±0.66) mm,with resultant increased target lesion revascularization (TLR) 12.2% and TVR 14.4%,significantly different from the Excel group; (2.47±0.56) mm,P <0.001,3.2%,P=0.006,4.9%,P=0.019,respectively.As a result there was a significant difference in MACE between the Taxus (20.0%) and Excel (10.3%,P=0.038) groups.Overall stent thrombosis was monitored in 11 patients (4.0%),with five in the Excel group (2.7%) and six in the Taxus group (6.7%).All stent thrombosis in the Excel group was classified as early,and all were defined as late in the Taxus group.Conclusion The Excel stent had lower rate of stent thrombosis,TLR,TVR,and composite MACE at 12-month after an indexed stenting procedure,compared to the Taxus stent.

更多
广告
作者 CHEN Shao-liang [1] Gary Mintz [2] Teguh Santoso [3] ZHANG Jun-jie [1] YE Fei [1] XU Ya-wei [4] FU Qiang [5] KAN Jing [1] Chitprapai Paiboon [6] ZHOU Yong [7] DING Shi-qin [8] Tak W Kwan [9] 学术成果认领
作者单位 Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing 210006, China [1] Cardiovascular Research Foundation, New York, NY, US [2] Department of Cardiology, Medistra Hospital, University of Indonesia Medical School, Jakarta, Indonesia [3] Department of Cardiology, Shanghai 10th People's Hospital,Shanghai 200072, China [4] Department of Cardiology, Xuzhou Central Hospital, Xuzhou,Jiangsu 221009, China [5] Department of Cardiology, Bangkok General Hospital, Bangkok,Thailand [6] Department of Cardiology, Zhangjiagang People's Hospital,Zhangjiagang, Jiangsu 215600, China [7] Department of Cardiology, Huainan Xinhua Hospital, Huainan,Anhui 232038, China [8] Department of Cardiology, Beth Israel Hospital, NewYork, USA [9]
分类号 S948
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2012.19.004
发布时间 2012-12-20(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览289
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年125卷19期

3382-3387页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷