• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Investigation of long-term implantation of BuMA stent in a porcine coronary model

摘要Background Stent-based delivery of sirolimus has been shown to reduce neointimal hyperplasia significantly.However,the long-term effect of the polymer is thought to initiate and sustain an inflammatory response and contribute to the occurrence of late complications.Our study aimed to evaluate the efficacy and safety of the BuMA biodegradable drug-coated sirolimus-eluting stent(BSES)for inhibiting neointimal hyperplasia in a porcine coronary model.Methods Four types of stents were implanted at random in different coronary arteries of the same pig:BSES(n=24),bare metal stent(BMS)(n=24),biodegradable polymer coated stent without drug(PCS)(n=24)and only poly(n-butyl methacrylate)base layer coated stent(EGS)(n=23).In total,26 animals underwent successful random placement of 95 oversized stents in the coronary arteries.Coronary angiography was performed after 28 days,90 days and 240 days of stent implantation.After 14 days,28 days,90 days and 240 days,6 animals at each timepoint were sacrificed for histomorphologic analysis.Results The 28-day,90-day and 240-day results of quantitative coronary angiography(QCA)showed reduction in luminal loss(LL)in the BSES group when compared with the BMS group;(0.20±0.35)mm vs.(0.82±0.51)mm(P=0.035),(0.20±0.30)mm vs.(0.93±0.51)mm(P=0.013),and(0.18±0.16)mm vs.(0.19±0.24)mm(P=0.889),respectively.By 28-day,90-day and 240-day histomorphomeric analysis results,there was also a corresponding significant reduction in neointimal tissue proliferation with similar injury scores of BSES compared with the BMS control;average neointimal area(0.90±0.49)mm2 vs.(2.16±1.29)mm2(P=0.049),(1.53±0.84)mm2 vs.(3.41±1.55)mm2(P=0.026),and(2.43±0.95)mm2 vs.(3.12±1.16)mm2(P=0.228),respectively.High magnification histomorphologic examination revealed similar inflammation scores and endothelialization scores in both the BSES and BMS groups.Conclusions The BuMA biodegradable drug-coated sirolimus-eluting stents can significantly reduce neointimal hyperplasia and in-stent restenosis.Re-endothelialization of the BuMA stent is as good as that of the BMS in the porcine coronary model due to the reduced inflammation response to the BuMA stent.

更多
广告
作者单位 Department of Cardiology,Peking University First Hospital,Beijing 100034,China [1] Department of Cardiology,Beijing Anzhen Hospital,Beijing 100029,China [2] Department of Cardiology,Peking University Shougang Hospital,Beijing 100144,China [3]
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2012.22.031
发布时间 2013-01-28
提交
  • 浏览182
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年125卷22期

4083-4087页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷