• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Multimodal magnetic resonance imaging for assessing lacunar infarction after proximal middle cerebral artery occlusion in a canine model

摘要:

Background A new lacunar infarction model was recently established in beagle dogs through proximal middle cerebral artery (MCA) occlusion by thrombus.This study aimed to characterize the model by multimodal magnetic resonance imaging (MRI) and to investigate its potential role for the future stroke research.Methods The left proximal MCA was embolized with an autologous thrombus in six beagles.Diffusion-weighted imaging (DWl) and T2-weighted imaging (T2Wl) were performed every half hour during the first six hours after occlusion,followed by three time points at 12 hours,24 hours,and one week.Perfusion-weighted imaging (PWl) and magnetic resonance angiography (MRA) were carried out at six hours,24 hours and one week.The PWI-DWl mismatch ratio was defined as (PWI-DWI)/DWI ischemic volume.Results Lacunar infarcts induced by MCA occlusion were located in the left caudate nucleus and internal capsule.All the lesions could be detected within two hours by DWI.Lesion volume on DWI increased in a time dependent manner,from (87.19±67.16) mm3 at one hour up to (368.98±217.05) mm3 at 24 hours (P=-0.009),while that on PWI gradually decreased from (7315.00±2054.38) mm3 at six hours to (4900.33±1319.71) mm3 at 24 hours and (3334.33±1195.11) mm3 at one week (P=0.002).The mismatch ratio was 41.93±22.75 at six hours after ischemia,showing "extensive mismatch",and decreased to 18.10+13.74 at 24 hours (P=0.002).No MCA recanalization was observed within 24 hours after MCA occlusion.Conclusions Lacunar infarction induced by proximal MCA occlusion could be detected early by DWI and was characterized by extensive PWI-DWI mismatch.Multimodal MRI is useful to demonstrate the natural evolution of PWI-DWI mismatch.This ischemic model could be further used for investigating early thrombolysis in lacunar stroke showing extensive mismatch.

更多
作者单位: Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China [1]
期刊: 《中华医学杂志(英文版)》2013年126卷2期 311-317页 SCIMEDLINEISTICCSCDBP
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/cma.j.issn.0366-6999.20121983
发布时间: 2013-04-19
基金项目:
This study was supported by the National Natural Science Foundation of China the Foundation of Research and Innovation Program for Postgraduates in Jiangsu Province
翻译满意度评价:
提交
  • 浏览:180
  • 下载:8

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷