• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Impact of uncontrolled blood pressure on diagnostic accuracy of coronary flow reserve for detecting significant coronary stenosis in hypertensive patients

摘要Baciground Impaired coronary flow reserve (CFR) in patients with hypertension may be caused by epicardial coronary stenosis or microvascular dysfunction.Antihypertensive treatment has been shown to improve coronary microvascular dysfunction.The aim of this study was to evaluate the impact of uncontrolled blood pressure (BP) on diagnostic accuracy of CFR for detecting significant coronary stenosis.Methods A total of 98 hypertensive patients scheduled for coronary angiography (CAG) due to chest pain were studied.Of them,45 patients had uncontrolled BP (defined as the office BP >140/90 mmHg (1 mmHg=0.133 kPa) in general hypertensive patients,or >130/80 mmHg in hypertensive individuals with diabetes mellitus),and the remaining 53 patients had well-controlled BP.CFR was measured in the left anterior descending coronary artery (LAD) during adenosine triphosphate-induced hyperemia by non-invasive transthoracic Doppler echocardiography (TTDE) within 48 hours prior to CAG.Significant LAD stenosis was defined as >70% luminal narrowing.Diagnostic accuracy of CFR for detecting significant coronary stenosis was analyzed with a receiver operating characteristic analysis.Results CFR was significantly lower in patients with uncontrolled BP than in those with well-controlled BP (2.1±0.6 vs.2.6±0.9,P <0.01).Multivariate linear regression analysis of the study showed that the value of CFR was independently associated with the angiographically determined degree of LAD stenosis (β=-0.445,P <0.0001) and the presence of uncontrolled BP (β=-0.272,P=0.014).With a receiver operating characteristic analysis,CFR <2.2 was the optimal cut-off value for detecting LAD stenosis in all hypertensive patients (AUC 0.83,95%C/0.75-0.91) with a sensitivity of 75%,a specificity of 78%,and an accuracy of 77%.A significant reduction of diagnostic specificity was observed in patients with uncontrolled BP compared with those with well-controlled BP (67% vs.93%,P=0.031).Conclusions CFR measurement by TTDE is valuable in the diagnosis of significant coronary stenosis in hypertensive patients.However,the diagnostic specificity is reduced in patients with uncontrolled BP.

更多
广告
作者单位 Department of Cardiology, Peking University Third Hospital, Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health; Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education, Beijing 100191,China [1]
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.20123043
发布时间 2013-04-26
提交
  • 浏览128
  • 下载20
中华医学杂志(英文版)

中华医学杂志(英文版)

2013年126卷5期

839-844页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷