• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Investigation on the optical scan condition for imaging of multi-slice spiral CT liver perfusion in rats

摘要Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions,and is usually performed as an adjunct to a conventional CT examination because of its high temporal and spatial resolution,simple protocol,good reproducibility,and ability to measure hemodynamic changes of liver tissues at the capillary level.Experimental rat models,especially those of induced liver cancer,are often used in studies of hemodynamic changes in liver cancer.Carcinogenesis in rats has a similar pathological progression and characteristics resembling those in human liver cancer; as a result,rat models are often used as ideal animal models in the study of human liver cancer.However,liver perfusion imaging in rats is difficult to perform,because rats' livers are so small that different concentrations,flow rates,and dose of contrast agents during the CT perfusion scanning can influence the quality of liver perfusion images in rats.The purpose of this study,therefore,was to investigate the optimal scan protocol for the imaging of hepatic perfusion using a deconvolution mathematical method in rats by comparing the results of rats in different injection conditions of the contrast agent,including concentration,rate and time.Methods Plain CT scan conditions in eighty 2-month-old male Wistar rats were 5.0 mm slice thickness,5.0 mm interval,1.0 pitch,120 kV tube voltage,60 mA tube current,512×512 matrix,and FOV 9.6 cm.Perfusion scanning was carried out with different concentrations of diatrizoate (19%,38%,57%,and 76%),different injection rates (0.3 and 0.5 mi/s),and different injection times (1,2-3,4-5,and 6 seconds).The above conditions were randomly matched and adjusted to determine the best perfusion scan protocol.Thrae-phase contrast-enhanced scanning was performed after CT perfusion.Histological examination of the liver tissues with hematoxylin and eosin stains was done after CT scanning.Results When the concentration of the contrast agent was 19% or 38%,no pseudo-color map was created.The viscosity increased when the concentration of the contrast agent was 76%; so it is difficult to inject the contrast agent at such a high concentration.Also no pseudo-color map was generated when the injection time was short (1,2-3,and 4-5 seconds)or the injection rate was low (0.3 mi/s).The best perfusion images and perfusion parameters were obtained during 50 seconds scanning.Each rat was given an injection of 57% diatrizoate at 0.5 mi/s via the tail vein using a high-pressure syringe for 6 seconds.The perfusion parameters included hepatic blood flow (HBF),hepatic blood volume (HBV),mean transit time (MTT) of the contrast agent,capillary permeability-surface area product (PS),hepatic arterial index (HAI),hepatic artery perfusion (HAP),and hepatic portal perfusion (HPP).All these parameters reflected the perfusion status of liver parenchyma in normal rats,Three phases of enhancement were modified according to the time-density curves (TDCs) of the perfusion imaging:hepatic arterial phase (7 seconds),hepatic portal venous phase (15 seconds),and a delayed phase (23-31 seconds).On examination by microscopy,the liver tissues were pathologically normal.Conclusions The appropriate protocol with multi-slice spiral CT liver perfusion reflected normal liver hemodynamics in rats.This study laid a solid foundation for further investigation of the physiological characteristics of liver cancer in a rat model,and was an important supplement to and reference for conventional contrast-enhanced CT scans.

更多
广告
作者单位 Department of Radiology, Beijing Jishuitan Hospital, the Fourth Clinical Medical College of Peking University, Beijing 100035,China [1] Department of Radiology, Second Affiliated Hospital, Harbin Medical University, Harbin, Heilongjiang 150086, China [2]
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.20121400
发布时间 2014-01-18
基金项目
This study was supported by a grant from Heilongjiang Educational Committee
提交
  • 浏览79
  • 下载32
中华医学杂志(英文版)

中华医学杂志(英文版)

2013年126卷24期

4742-4746页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷