Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries

摘要Background To overcome the drawbacks of permanent stents,biodegradable stents have been studied in recent years.The bioabsorbable polymer vascular scaffold (BVS) was the first bioabsorbable stent to undergo clinical trials,demonstrating safety and feasibility in the ABSORB studies.Iron can potentially serve as the biomaterial for biodegradable stents.This study aimed to assess the short-term safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries.Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine,respectively.Two stents of the same metal base were implanted into one animal.At 28 days the animals were sacrificed after coronary angiography,and histopathological examinations were performed.Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs.(0.45±0.18)mm,P=0.878),neointimal area ((2.55±0.91) mm2 vs.(3.04±1.15) mm2,P=0.360) and percentage of area stenosis ((44.50±11.40)% vs.(46.00±17.95)%,P=0.845) were not significantly different between the iron stents and VISION stents.There was no inflammation,thrombosis or necrosis in either group.The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs.0.88±0.99,P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups.The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs.(65.00±22.04)%,P=0.057),but the difference was not statistically significant.Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge,consistent with iron degradation.No abnormal histopathological changes were detected in coronary arteries or major organs.Conclusions The biodegradable iron stent has good biocompatibility and short-term safety and efficacy in the miniswine coronary artery.Corrosion of iron stents is observed at four weeks and no signs of organ toxicity related to iron degradation were noted.

更多
广告
作者单位 State Key Laboratory of Cardiovascular Disease, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China [1] Department of Cardiology, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China [2] Department of Pathology, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China [3] Experimental Animal Center, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China [4] Department of Pathology, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China;Department of Cardiology, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China [5]
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.20131120
发布时间 2014-01-18
基金项目
a grant from the National 863 Program of China
提交
  • 浏览64
  • 下载16
中华医学杂志(英文版)

中华医学杂志(英文版)

2013年126卷24期

4752-4757页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷