• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Integrated positron emission tomography and computed tomography in preoperative lymph node staging of non-small cell lung cancer

摘要Background Integrated positron emission tomography and computed tomography (PET/CT) is increasingly used for the preoperative nodal staging of non-smail cell lung cancer (NSCLC).The aim of this study was to evaluate the accuracy of PET/CT in comparison with CT in detection of nodal metastasis and preoperative nodal staging in patients with NSCLC,and to analyze the causes of the PET/CT false-negative and false-positive results.Methods Consecutive patients with pathologically proven NSCLC who underwent staging using PET/CT from July 2008 to February 2012 were evaluated retrospectively.Nodal staging was pathologically confirmed on tissue specimens obtained at thoracotomy.The accuracy of PET/CT and CT in the assessment of intrathoracic nodal involvement was determined using histological results as the reference standard.Logistic regression was used to define the causes of the false-negative and false-positive results.Results A total of 528 lymph node stations were evaluated in 101 patients.Lymph nodes were positive for malignancy in 43 out of 101 patients (42.6%),and 101 out of 528 nodal stations (19.2%).PET/CT was significantly more accurate for nodal staging than CT.The sensitivity,specificity,positive and negative predictive values,and accuracy of PET/CT for detecting nodal metastasis were 51.5%,95.8%,74.3%,89.3%,and 87.3% and the corresponding data by CT were 45.5%,87.1%,45.5%,87.1%,and 79.2%,respectively.PET/CT confers significantly higher specificity,positive predictive value,and accuracy than CT in detecting nodal metastasis.False-negative results by PET/CT are significantly associated with smaller lymph node size,whereas false-positive results are related to a combination of inflammatory disorders and larger lymph node size.Conclusion PET/CT confers significantly higher accuracy than CT in nodal staging,and is more specific and accurate than CT in detecting nodal metastasis but has a low sensitivity and high false-negative rate.

更多
广告
作者单位 Department of General Internal Medicine,Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China [1] Department of Respiratory Medicine,Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China [2] Department of Nuclear Medicine,Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China [3]
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.20131691
发布时间 2014-03-19
提交
  • 浏览93
  • 下载16
中华医学杂志(英文版)

中华医学杂志(英文版)

2014年127卷4期

607-613页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷