• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Inaccuracy of doppler echocardiographic estimates of pulmonary artery pressures in adult atrial septal defect patients with pulmonary arterial hypertension

摘要Background While echocardiography has been a pivotal screening test in pulmonary arterial hypertension (PAH),the presence of structural cardiac defects may affect the ability to reliably predict pulmonary artery pressures (PAPs).This study sought to evaluate the accuracy of Doppler echocardiography (DE) for estimating PAPs in adult atrial septal defect (ASD) patients with PAH.Methods A prospective study was carried out to compare the echocardiographic assessment of PAP with the same pressures obtained by right heart catheterization (RHC) in adult ASD patients with PAH who underwent simultaneous DE and RHC.Bland-Altman analyses were performed to evaluate the agreement between DE and RHC measurements of PAPs.Results Two hundred and fifty-seven patients were included in the study.A significant overestimation of the systolic pulmonary arterial pressure (sPAP) and mean pulmonary artery pressure (mPAP) was reported by echocardiography compared with those by catheterization ((81.8±26.9) mmHg vs.(72.9±26.9) mmHg,P <0.01; (51.9±16.4) mmHg vs.(41.4±17.2) mmHg,P <0.01,respectively).Twenty-one percent (55/257) of the patients had PAH when estimated by echocardiography whereas showed normal results in the subsequent catheterization test.Using Bland-Altman analytic methods,the bias for the echocardiographic assessment of the sPAP was 9.1 mmHg with 95% limits of agreement ranging from-24.4 to 42.6 mmHg.For mPAP measurement,the bias was 10.5 mmHg with 95% limits of agreement ranging from-12.4 to 33.4 mmHg.On multiple linear regression analysis,age,gender,body surface area,ASDs' diameter,PVR,diastolic blood pressure,and echocardiographic assessment of right atrial pressure (RAP) explained 68.8% of the total variability in the model (r2=0.688,P <0.01).Conclusion Inaccuracy was frequently reported in Doppler echocardiographic assessment of the PAP in adult ASD patients with PAH and was often associated with age,gender,body surface area,ASDs' diameter,pulmonary vascular resistance,diastolic blood pressure and echocardiographic estimation of RAP.

更多
广告
作者单位 Department of Cardiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences & Guangdong Cardiovascular Institute, Guangzhou, Guangdong 510100, China [1] Department of Cardiovascular Surgery , Guangdong General Hospital, Guangdong Academy of Medical Sciences & Guangdong Cardiovascular Institute, Guangzhou, Guangdong 510100, China [2]
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.20140992
发布时间 2014-10-28
基金项目
This study was supported by a national grant from the Ministry of Science and Technology
提交
  • 浏览84
  • 下载20
中华医学杂志(英文版)

中华医学杂志(英文版)

2014年127卷19期

3389-3395页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷