• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Comparison of ocular modulation transfer function determined by a ray-tracing aberrometer and a double-pass system in early cataract patients

摘要Background The evaluation of retinal image quality in cataract eyes has gained importance and the clinical modulation transfer functions (MTF) can obtained by aberrometer and double pass (DP) system.This study aimed to compare MTF derived from a ray tracing aberrometer and a DP system in eady cataractous and normal eyes.Methods There were 128 subjects with 61 control eyes and 67 eyes with early cataract defined according to the Lens Opacities Classification System Ⅲ.A laser ray-tracing wavefront aberrometer (iTrace) and a double pass (DP) system (OQAS) assessed ocular MTF for 6.0 mm pupil diameters following dilation.Areas under the MTF (AUMTF) and their correlations were analyzed.Stepwise multiple regression analysis assessed factors affecting the differences between iTrace-and OQAS-derived AUMTF for the early cataract group.Results For both early cataract and control groups,iTrace-derived MTFs were higher than OQAS-derived MTFs across a range of spatial frequencies (P <0.01).No significant difference between the two groups occurred for iTrace-derived AUMTF,but the early cataract group had significantly smaller OQAS-derived AUMTF than did the control group (P <0.01).AUMTF determined from both the techniques demonstrated significant correlations with nuclear opacities,higher-order aberrations (HOAs),visual acuity,and contrast sensitivity functions,while the OQAS-derived AUMTF also demonstrated significant correlations with age and cortical opacity grade.The factors significantly affecting the difference between iTrace and OQAS AUMTF were root-mean-squared HOAs (standardized beta coefficient=-0.63,P <0.01) and age (standardized beta coefficient=0.26,P <0.01).Conclusions MTFs determined from a iTrace and a DP system (OQAS) differ significantly in early cataractous and normal subjects.Correlations with visual performance were higher for the DP system.OQAS-derived MTF may be useful as an indicator of visual performance in early cataract eyes.

更多
广告
作者单位 Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Science Key Laboratory, Capital Medical University, Beijing 100730, China [1] College of Optometry, Midwestern University, Glendale, Arizona, United States [2]
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.20141492
发布时间 2014-10-28
基金项目
This study was supported by a grant from the Health and Public Welfare Industry Research Program of the Ministry of Health of China
提交
  • 浏览115
  • 下载84
中华医学杂志(英文版)

中华医学杂志(英文版)

2014年127卷19期

3454-3458页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷