医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Comparisons in finite element analysis of minimally invasive, locking,and non-locking plates systems used in treating calcaneal fractures of Sanders type Ⅱ and type Ⅲ

摘要Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasive,locking,and non-locking plating systems used for fixing Sanders type Ⅱ and type Ⅲ calcaneal fractures.Finite element analysis was used for comparing the three types of plating systems.This study helped in guiding the clinical management of calcaneal fractures.Methods The CT data acquired from a volunteer was used to construct a finite element model of calcaneus.The fracture lines were made according to Sanders type Ⅱ (A,B,C) and type Ⅲ (AB,AC,BC) and six calcaneal fractures models were constructed accordingly.Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws,Y-size non-locking plating,and locking plating) and then fixed to these fracture models with the help of clinical principles.The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws.Then,the neutral force was applied on established methods.The displacement and presses distribution condition in various plating models were analyzed and compared.Results The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit,indicating that the three methods were suitable for application.Compared with the locked and unlocked plates,the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation.The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.Conclusions The minimally invasive plating method could be a better alternative method in treating Sanders type Ⅱ and type Ⅲ calcaneal fractures.The observed stiffness of locking plate was not obviously stronger than unlocked plate.

更多
广告
作者单位 Department of Orthopedics and Traumatology, Nanfang Hospital,Southern Medical University, Guangzhou, Guangdong 510515, China;Department of Orthopaedics, The Ordos Center Hospital, The Ordos Clinic Medical College, Inner Mongolia Medical University, Ordos,Inner Mongolia 017000, China [1] Department of Orthopedics and Traumatology, Nanfang Hospital,Southern Medical University, Guangzhou, Guangdong 510515, China [2] Department of Orthopaedics, The Ordos Center Hospital, The Ordos Clinic Medical College, Inner Mongolia Medical University, Ordos,Inner Mongolia 017000, China [3]
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.20141641
发布时间 2014-12-05(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览137
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2014年127卷22期

3894-3901页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷