• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Study of Bone-screw Surface Fixation in Lumbar Dynamic Stabilization

摘要Background:We aimed to use the animal model of dynamic fixation to examine the interaction of the pedicle screw surface with surrounding bone,and determine whether pedicle screws achieve good mechanical stability in the vertebrae.Methods:Twenty-four goats aged 2-3 years had Cosmic(R) pedicle screws implanted into both sides of the L2-L5 pedicles.Twelve goats in the bilateral dynamic fixation group had fixation rods implanted in L2-L3 and L4-L5.Twelve goats in the unilateral dynamic fixation group had fixation rods randomly fixed on one side of the lumbar spine.The side that was not implanted with fixation rods was used as a static control group.Results:In the static control group,new bone was formed around the pedicle screw and on the screw surface.In the unilateral and bilateral dynamic fixation groups,large amounts of connective tissue formed between and around the screw threads,with no new bone formation on the screw surface; the pedicle screws were loose after the fixed rods were removed.The bone mineral density and morphological parameters of the region of interest (ROI) in the unilateral and bilateral dynamic fixation group were not significantly different (P > 0.05),but were lower in the fixed groups than the static control group (P < 0.05).This showed the description bone of the ROI in the static control group was greater than in the fixation groups.Under loading conditions,the pedicle screw maximum pull force was not significantly different between the bilateral and unilateral dynamic fixation groups (P > 0.05); however the maximum pull force of the fixation groups was significantly less than the static control group (P < 0.01).Conclusions:Fibrous connective tissue formed at the bone-screw interface under unilateral and bilateral pedicle dynamic fixation,and the pedicle screws lost mechanical stability in the vertebrae.

更多
广告
作者单位 Department of Stomatology, The Second Hospital of Jilin University, Changchun, Jilin 130041, China [1] Department of Orthopedics, The Second Hospital of Jilin University, Changchun, Jilin 130041, China [2] Traditional Chinese Medicine Academy of Science of Jilin Provine, Changchun, Jilin 130041, China [3]
栏目名称
DOI 10.4103/0366-6999.150107
发布时间 2015-03-17
提交
  • 浏览47
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2015年128卷3期

368-372页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷