• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

摘要Background:Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms.Postoperative endoleak is the most common complication of EVAR.Computed tomography angiography (CTA),which is routine for follow-up,has side effects (e.g.,radiation) and also has a certain percentage of missed diagnosis.Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA.To investigate the advantages of CEUS,we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods:Post-EVAR patients,who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014.All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination.Size,location,microbubble dispersion,and hemodynamic characteristics of leaks were recorded.Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher's exact test and clinical outcomes of all patients were followed up.Results:Sixteen patients were enrolled,and 12 (75%) had endoleaks with verified types by CEUS.Among 12 cases of endoleaks were positive by CEUS,10 were CDFI-positive,and the four CEUS-negative cases were all negative by CDFI.The diagnostic values of CEUS and CDFI were statistically different (P =0.008).Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results.One patient with type Ⅲ endoleak had open surgery when endovascular repair failed.Conclusions:CEUS is a new,safe,and effective means for detection ofendoleaks post-EVAR.This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.

更多
广告
作者单位 Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100730, China [1] Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100730, China [2]
栏目名称 Original Articles
DOI 10.4103/0366-6999.164935
发布时间 2015-10-16
提交
  • 浏览81
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2015年128卷18期

2491-2497页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷