A Dosimetric Comparison between Conventional Fractionated and Hypofractionated Image-guided Radiation Therapies for Localized Prostate Cancer

摘要Background:Image-guided radiation therapy (IGRT) is the preferred method for curative treatment of localized prostate cancer,which could improve disease outcome and reduce normal tissue toxicity reaction.IGRT using cone-beam computed tomography (CBCT) in combination with volumetric-modulated arc therapy (VMAT) potentially allows smaller treatment margins and dose escalation to the prostate.The aim of this study was to compare the difference of dosimetric diffusion in conventional IGRT using 7-field,step-and-shoot intensity-modulated radiation therapy (IMRT) and hypofractionated IGRT using VMAT for patients with localized prostate cancer.Methods:We studied 24 patients who received 78 Gy in 39 daily fractions or 70 Gy in 28 daily fractions to their prostate with/without the seminal vesicles using IMRT (n =12) or VMAT (n =12) for prostate cancer between November 2013 and October 2015.Image guidance was performed using kilovoltage CBCT scans equipped on the linear accelerator.Offline planning was performed using the daily treatment images registered with simulation computed tomography (CT) images.A total of 212 IMRT plans in conventional cohort and 292 VMAT plans in hypofractionated cohort were enrolled in the study.Dose distributions were recalculated on CBCT images registered with the planning CT scanner.Results:Compared with 7-field,step-and-shoot IMRT,VMAT plans resulted in improved planning target volume (PTV) D95% (7663.17 ± 69.57 cGy vs.7789.17 ± 131.76 cGy,P < 0.001).VMAT reduced the rectal D25 (P < 0.001),D35 (P < 0.001),and D50 (P < 0.001),bladder V50 (P < 0.001),D25 (P =0.002),D35 (P =0.028),and D50 (P =0.029).However,VMAT did not statistically significantly reduce the rectal V50,compared with 7-field,step-and-shoot IMRT (25.02 ± 5.54% vs.27.43 ± 8.79%,P =0.087).Conclusions:To deliver the hypofractionated radiotherapy in prostate cancer,VMAT significantly increased PTV D95% dose and decreased the dose of radiation delivered to adjacent normal tissues comparing to 7-field,step-and-shoot IMRT.Daily online image-guidance and better management of bladder and rectum could make a more precise treatment delivery.

更多
广告
作者单位 Department of Radiation Oncology, Beijing Hospital, Beijing 100730, China [1]
栏目名称
DOI 10.4103/0366-6999.183429
发布时间 2016-07-29
提交
  • 浏览21
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷12期

1447-1454页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷