Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures

摘要Background:Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures,this study was to compare the mechanical properties of anteromedial,anterolateral,and posterior plating for humeral shaft fractures.Methods:A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404,composite bone).Atotal of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups:A,B,and C (n =8 in each group) for anteromedial,anterolateral,and posterior plating,respectively.All sawbones were subjected to horizontal torsional fatigue tests,horizontal torsional and axial compressive fatigue tests,four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests.Results:In the horizontal torsional fatigue tests,the mean torsional angle amplitude in Groups A,B,and C were 6.12°,6.53°,and 6.81°.In horizontal torsional and axial compressive fatigue tests,the mean torsional angle amplitude in Groups A,B,and C were 5.66°,5.67°,and 6.36°.The mean plate displacement amplitude was 0.05 mm,0.08 mm,and 0.10 mm.Group A was smaller than Group C (P < 0.05).In AP four-point bending fatigue tests,the mean plate displacement amplitude was 0.16 mm,0.13 mm,and 0.20 mm.Group B was smaller than Group C (P < 0.05).In ML four-point bending fatigue tests,the mean plate displacement amplitude were 0.16 mm,0.19 mm,and 0.17 mm.In horizontal torsional destructive tests,the mean torsional rigidity in Groups A,B,and C was 0.82,0.75,and 0.76 N.m/deg.The yielding torsional angle was 24.50°,25.70°,and 23.86°.The mean yielding torque was 18.46,18.05,and 16.83 N·m,respectively.Conclusions:Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the anterolateral plating group.We can suggest that anteromedial plating is a clinically safe and effective way for humeral shaft fractures.

更多
广告
作者单位 Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing 100020, China [1]
栏目名称
DOI 10.4103/0366-6999.186645
发布时间 2016-08-23(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览31
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷15期

1850-1855页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷