Echocardiographic Follow-up of Robotic Mitral Valve Repair for Mitral Regurgitation due to Degenerative Disease

摘要Background:Mitral valve (MV) repair can now be carried out through small incisions with the use of robotic assistance.Previous reports have demonstrated the excellent clinical result of robotic MV repair for degenerative mitral regurgitation (MR).However,there has been limited information regarding the echocardiographic follow-up of these patients.The present study was therefore to evaluate the echocardiographic follow-up outcomes after robotic MV repair in patients with MR due to degenerative disease of the MV.Methods:A retrospective analysis was undertaken using data from the echocardiographic database of our department.Between March 2007 and February 2015,84 patients with degenerative MR underwent robotic MV repair.The repair techniques included leaflet resection in 67 patients (79.8%),artificial chordae in 20 (23.8%),and ring annuloplasty in 79 (94.1%).Eighty-one (96.4%) of the 84 patients were eligible for echocardiographic follow-up assessment,and no patients were lost to follow-up.Results:At a median echocardiographic follow-up of 36.0 months (interquartile range 14.3-59.4 months),four patients (4.9%) developed recurrent mild MR,and no patients had more than mild MR.Mean MR grade,left atrial diameter (LAD),left ventricular end-diastolic diameter (LVEDD),and left ventricular ejection fraction (LVEF) were significantly decreased when compared with preoperative values.Mean MR grade decreased from 3.96 ± 0.13 to 0.17 ± 0.49 (Z =-8.456,P < 0.001),LAD from 43.8 ± 5.9 to 35.5 ± 3.8 mm (t =15.131,P < 0.001),LVEDD from 51.0 ± 5.0 to 43.3 ± 2.2 mm (t =14.481,P < 0.001),and LVEF from 67.3 ± 7.0% to 63.9 ± 5.1% (t =4.585,P < 0.001).Conclusion:Robotic MV repair for MR due to degenerative disease is associated with a low rate of recurrent MR,and a significant improvement in MR grade,LAD,and LVEDD,but a significant decrease in LVEF at echocardiographic follow-up.

更多
广告
作者单位 Department of Cardiovascular Surgery, Chinese People's Liberation Army General Hospital, Beijing 100853, China [1]
栏目名称
DOI 10.4103/0366-6999.189909
发布时间 2016-10-24
提交
  • 浏览24
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷18期

2199-2203页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷