• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration

摘要Background:Accuracy of implant placement in total knee arthroplasty (TKA) is crucial.Traditional extramedullary alignment instruments are fairly effective for achieving the desired mean tibial component coronal alignment.We modified the traditional tibial plateau resection technique and evaluated its effect on alignment restoration.Methods:Two hundred and eighty-two primary TKAs in our hospital between January 2013 and December 2014 were enrolled in this retrospective study.Group A consisted of 128 primary TKAs performed by one senior surgeon.Preoperative measurement of the tibial resection was conducted on radiographs,and the measured thicknesses of the lateral and medial plateau resection were used to place the tibial alignment guide.Group B consisted of 154 primary TKAs performed by the other senior surgeon,using a traditional tibial plateau resection technique.In all patients,an extramedullary guide was used for tibial resection,and preoperative and postoperative full-leg standing radiographs were used to assess the hip-knee-ankle angle (HKA),femoral component alignment angle (FA),and tibial component alignment angle (TA).A deviation ≥3° was considered unsatisfactory.Data were analyzed by unpaired Student's t-test.Results:The mean postoperative H KA and TA angles were significantly different between Groups A and B (178.2 ± 3.2° vs.177.0 ± 3.0°,t =2.54,P =0.01;89.3 ± 1.8° vs.88.3 ± 2.0°,t =3.75,P =0.00,respectively).The mean postoperative FA was 88.9 ± 2.5° in Group A and 88.9 ± 2.6° in Group B,and no significant difference was detected (t =0.10,P =0.92).There were 90 (70.3%) limbs with restoration of the mechanical axis to within 3° of neutral alignment and 38 (29.7%) outliers (>3° deviation) in Group A,whereas there were 89 (57.8%) limbs with restoration of the mechanical axis to within 3° of neutral alignment and 65 (42.2%) outliers (>3° deviation) in Group B.The severity of the preoperative alignment deformity was a strong predictor for postoperative alignment.Conclusions:Using conventional surgical instruments,preoperative measurement of resection thickness of the tibial plateau on radiographs could improve the accuracy of conventional surgical techniques.

更多
广告
作者单位 Department of Joint Surgery, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong 510080, China [1]
栏目名称 Original Articles
DOI 10.4103/0366-6999.192789
发布时间 2016-11-30
基金项目
This study was supported by grants from the Natural Science Foundation of Guangdong Province the Science and Technology Planning Project of Guangdong Province
提交
  • 浏览23
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷21期

2524-2529页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷