• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Three-dimensional Fluoroscopy-based Navigation for the Pedicle Screw Placement in Patients with Primary Invasive Spinal Tumors

摘要Background:Although pedicle screw placement (PSP) is a well-established technique for spine surgery,the treatment of patients with primary invasive spinal tumor (PIST) has high surgical risks secondary to destroyed pedicles.Intraoperative three-dimensional fluoroscopy-based navigation (ITFN) system permits safe and accurate instrumentation of the spine with the advantage of obtaining intraoperative real-time three-dimensional images and automatic registration.The aim of this study is to evaluate the feasibility and accuracy of PSP using ITFN system for patients afflicted with PIST in the thoracic spine.Methods:Fifty-one patients diagnosed with PISTs were retrospectively analyzed,and 157 pedicles screws were implanted in 23 patients using the free-hand technique (free-hand group) and 197 pedicle screws were implanted in 28 patients using the ITFN system (ITFN group).Modified classification of Gertzbein and Robbins was used to evaluate the accuracy of PSP,and McCormick classification was applied for assessment of neurological function.Demographic data and factors affecting accuracy of screw insertion were compared using independent t-test while comparison of accuracy of screw insertion between the two groups was analyzed with Chi-square test.Results:Of 51 patients,39 demonstrated improved neurological status and the other 12 patients reported that symptoms remained the same.In the free-hand group,145 screws (92.4%) were Grade Ⅰ,9 screws (5.7%) were Grade Ⅱ,and 3 screws (1.9%) were Grade Ⅲ.In the ITFN group,192 screws (97.4%) were Grade Ⅰ,5 screws (2.6%) were Grade Ⅱ,and no Grade Ⅲ screw was detected.Statistical analysis showed that the accuracies of pedicle screws in the two groups are significantly different (x2 =4.981,P =0.026).Conclusions:The treatments of PISTs include total tumor resection and reconstruction of spine stability.The ITFN system provides a high accuracy of pedicle screw placement.

更多
广告
作者单位 Department of Neurosurgery Beijing Jishuitan Hospital, Fourth Medical College of Peking University Beijing 100035, China [1] Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, China;China National Clinical Research Center for Neurological Diseases, Beijing 100050, China [2]
栏目名称 Original Articles
DOI 10.4103/0366-6999.192777
发布时间 2016-11-30
基金项目
the grant from the Ministry of Science and Technology of China
提交
  • 浏览18
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷21期

2552-2558页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷