Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model

摘要Background:Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis.Based on a patient-specific CFD model,the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment.Methods:Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed.The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups:the normal,stenotic,and stented groups.Hemodynamic parameters including pressure distribution,velocity,wall shear stress (WSS),and mass flow rate (MFR) were extracted.The data of hemodynamic parameters were expressed as median (interquartile range),and Mann-Whitney U-test was used for analysis.Results:Totally,6 normal,12 stenotic,and 6 stented TRAs were included in the analysis.TRAS presented nonuniform pressure distribution,adverse pressure gradient across stenosis throat,flow vortex,and a separation zone at downstream stenosis.Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14,3.30] vs.1.06 [0.89,1.15] m/s,256.5 [149.8,349.4] vs.41.7 [37.8,45.3] Pa at end diastole,P =0.001;3.25 [2.67,3.56] vs.1.65 [1.18,1.72] m/s,281.3 [184.3,3 64.7] vs.65.8 [61.2,71.9] Pa at peak systole,P =0.001) and lower minimal WSS and MFRs (0.07 [0.03,0.13] vs.0.52 [0.45,0.67] Pa,1.5 [1.0,3.0] vs.11.0 [8.0,11.3] g/s at end diastole,P =0.001;0.08 [0.03,0.19] vs.0.70 [0.60,0.81] Pa,2.0 [1.3,3.3] vs.16.5 [13.0,20.3] g/s at peak systole,P =0.001) as compared to normal arteries.Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS.Conclusions:Hemodynamic factors were significantly changed in severe TRAS.Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.

更多
广告
作者单位 Organ Transplant Center, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong 510080, China [1]
栏目名称
DOI 10.4103/0366-6999.196569
发布时间 2017-02-24(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览69
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷