• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Corneal Biomechanical Parameters and Asymmetric Visual Field Damage in Patients with Untreated Normal Tension Glaucoma

摘要Background:High intraocular pressure (IOP) and low central corneal thickness (CCT) are important validated risk factors for glaucoma,and some studies also have suggested that eyes with more deformable corneas may be in higher risk of the development and worsening of glaucoma.In the present study,we aimed to evaluate the association between corneal biomechanical parameters and asymmetric visual field (VF) damage using a Corvis-ST device in patients with untreated normal tension glaucoma (NTG).Methods:In this observational,cross-sectional study,44 newly diagnosed NTG patients were enrolled.Of these,31 had asymmetric VF damage,which was defined as a 5-point difference between the eyes according to the Advanced Glaucoma Intervention Study scoring system.Corneal biomechanical parameters were obtained using a Corvis-ST device,such as time from start until the first and second applanation is reached (time A1 and time A2,respectively),cord length of the first and second applanation (length A1 and length A2,respectively),corneal speed during the first and second applanation (velocity A1 and velocity A2,respectively),time from start until highest concavity is reached (time HC),maximum amplitude at the apex of highest concavity (def ampl HC),distance between the two peaks at highest concavity (peak dist HC),and central concave curvature at its highest concavity (radius HC).Results:Time A1 (7.19 ± 0.28 vs.7.37 ± 0.41 ms,P=0.010),length A1 (1.73 [1.70-1.76] vs.1.78 [1.76-1.79] mm,P=0.007),length A2 (1.58 [1.46-1.70] vs.1.84 [1.76-1.92] mm,P < 0.001),peak dist HC (3.53 [3.08-4.00] vs.4.33 [3.92-4.74] mm,P =0.010),and radius HC (6.20 ± 0.69 vs.6.59 ± 1.18 mm,P =0.032) were significantly lower in the worse eyes than in the better eyes,whereas velocity A 1 and def ampl HC were significantly higher (0.156 [0.149-0.163] vs.0.145 [0.138-0.152] m/s,P =0.002 and 1.1 9 ± 0.13 vs.1.15 ± 0.13 mm,P =0.005,respectively).There was no significant difference in time A2,velocity A2,and time HC between the two groups.In addition,no difference was observed in IOP,CCT,and axial length.In the univariate and multivariate analyses,some of the Corvis-ST parameters,including time A 1 and def ampl HC,were correlated with known risk factors for glaucoma,and there was also a significant positive correlation between def ampl HC and age.Conclusions:There were differences in dynamic corneal response parameters but not IOP or CCT between the paired eyes of NTG patients with asymmetric VF damage.We suggest that the shape of the cornea is more easily altered in the worse eyes of asymmetric NTG patients.

更多
广告
作者单位 Department of Ophthalmology, Peking University First Hospital, Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100034, China [1] Department of Ophthalmology, Beijing Tsinghua Changgung Hospital, Beijing 102218, China [2]
栏目名称
DOI 10.4103/0366-6999.198920
发布时间 2017-03-13
提交
  • 浏览19
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2017年130卷3期

334-339页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷