医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors

摘要Background:Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully,but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations.This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors.Methods:Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled.The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast,and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode.Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A.In addition,filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A.The total radiation dose,total iodine load,contrast injection speed,and maximum injection pressure were compared between the two groups.The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality.Results:The total radiation dose,total iodine load,injection speed,and maximum injection pressure for Group A were decreased by 19%,15%,34.4%,and 18.3%,respectively.The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV.At this level,the CT values in the abdominal aorta and its three branches,the portal vein and its two branches,and the inferior vena cava were all greater than 340 hounsfield unit (HU).The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t =0.36 and-1.716 for liver,0.153 and-1.546 for pancreas,and 2.427 and 0.866 for renal cortex,all P > 0.05).Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t =-8.11 for liver,-7.83 for pancreas,and-5.38 for renal cortex,all P < 0.05).However,the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all >3,indicating clinically acceptable image quality.Conclusions:Single-phase,dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

更多
广告
作者单位 Imaging Center, Beijing Children's Hospital, Capital Medical University, Beijing 100045, China [1]
栏目名称
DOI 10.4103/0366-6999.202731
发布时间 2017-04-25(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览55
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2017年130卷7期

823-831页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷