医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness

摘要Background:Evaluating the hemodynamic status and predicting fluid responsiveness are important in critical ultrasound assessment of shock patients.Transthoracic echocardiography with noninvasive diagnostic parameters allows the assessment of volume responsiveness.This study aimed to assess the hemodynamic changes in the liver and systemic hemodynamic changes during fluid challenge and during passive leg raising (PLR) by measuring hepatic venous flow (HVF) velocity.Methods:This is an open-label study in a tertiary teaching hospital.Shock patients with hypoperfusion who required fluid challenge were selected for the study.Patients <18 years old and those with contraindications to PLR were excluded from the study.Baseline values were measured,PLR tests were performed,and 500 ml of saline was infused over 30 min.Parameters associated with cardiac output (CO) in the left ventricular outflow tract were measured using the Doppler method.In addition,HVF velocity and right ventricular function parameters were determined.Results:Middle hepatic venous (MHV) S-wave velocity was positively correlated in all patients with CO at baseline (r=0.706,P < 0.01) and after volume expansion (r =0.524,P =0.003).CO was also significantly correlated with MHV S-wave velocity in responders (r =0.608,P < 0.01).During PLR,however,hepatic venous S-wave velocity did not correlate with CO.For the parameter ΔMHV D (increase in change in MHV D-wave velocity after volume expansion),defined as (MHV DafterVE-MHV DBaseline)/MHV DBaseline × 100%,>21% indicated no fluid responsiveness,with a sensitivity of 100%,a specificity of 71.2%,and an area under the receiver operating characteristic curve of 0.918.Conclusions:During fluid expansion,hepatic venous S-wave velocity can be used to monitor CO,whether or not it is increasing.AMHV D ≥21% indicated a lack of fluid responsiveness,thus helping to decide when to stop infusions.

更多
广告
作者单位 Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China [1]
栏目名称
DOI 10.4103/0366-6999.205848
发布时间 2017-06-13(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览136
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2017年130卷10期

1202-1210页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷