Comparison of Space Glucose Control and Routine Glucose Management Protocol for Glycemic Control in Critically Ⅲ Patients: A Prospective, Randomized Clinical Study

摘要Background:The Space Glucose Control (SGC) system is a computer-assisted device combining infusion pumps with the enhanced Model Predictive Control algorithm to achieve the target blood glucose (BG) level safely.The objective of this study was to evaluate the efficacy and safety of glycemic control by SGC with customized BG target range of 5.8-8.9 mmol/L in the critically ill patients.Methods:It is a randomized controlled trial of seventy critically ill patients with mechanical ventilation and hyperglycemia (BG > 9.0 mmol/L).Thirty-six patients in the SGC group and 34 in the routine glucose management group were observed for three consecutive days.Target BG for both groups was 5.8-8.9 mmol/L.The primary outcome was the percentage time in the target range.Results:The percentage time within BG target range in the SGC group (69 ± 15%) was significantly higher than in the routine management group (52 ± 24%;P < 0.01).No measurement was <2.2 mmol/L,and there was only one episode of hypoglycemia (2.3-3.3 mmol/L) in each group.The average BG was significantly lower in the SGC group (7.8 ± 0.7 mmol/L) than in the routine management group (9.1 ± 1.6 mmol/L,P < 0.001).Target BG level was reached earlier in the SGC group than routine management group (2.5 ± 2.9 vs.12.1 ± 15.3 h,P =0.001).However,the SGC group performed worse for daily insulin requirement (59.8 ± 39.3 vs.28.4 ± 36.7 U,P =0.001)and sampling interval (2.0 ± 0.5 vs.3.7 ± 0.5 h,P < 0.001) than the routine management group did.Multiple linear regression showed that the intervention group remained a significant individual predictor (P < 0.001) of the percentage time in target range.Conclusions:The SGC system,with a BG target of 5.8-8.9 mmol/L,resulted in effective and reliable glycemic control with few hypoglycemic episodes in critically ill patients with mechanical ventilation and hyperglycemia.However,the workload was increased.Trial Registration:http://www.clinicaltrials.gov,NCT 02491346;https://www.clinicaltrials.gov/ct2/show/NCT02491346?term=NCT0 2491346&cond=Hyperglycemia&cntry1=ES%3ACN&rank=1.

更多
广告
作者单位 Medical Intensive Care Unit, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100730, China;Critical Care Center, 302 Military Hospital of China, Beijing 100039, China [1] Medical Intensive Care Unit, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100730, China [2]
栏目名称 Original Articles
DOI 10.4103/0366-6999.213422
发布时间 2017-09-27
提交
  • 浏览34
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2017年130卷17期

2041-2049页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷