• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Effects of Repetitive Transcranial Magnetic Stimulation Treatment on Event-Related Potentials in Schizophrenia

摘要Background:Repetitive transcranial magnetic stimulation (rTMS) and event-related potentials (ERPs) are a noninvasive technique that widely used in neurophysiological field.Although rTMS has shown clinical utility for a number of neurological conditions,Recently,there was little understanding of the the efficacy ofrYMS on Schizophrenia(SZ) and the change of ERP between before and after rTMS treatment.The objective of this study was to investigate the characteristics of N400,mismatch negativity (MMN),and P300 before and after treatment with rTMS in SZ.Methods:One hundred and twenty-seven SZ patients hospitalized in Shanghai Mental Health Center from March 2015 to July 2017,divided into two groups (85 patients were recruited as rTMS group and 42 were recruited as sham rTMS [ShrTMS] group) and 76 normal controls (NCs) who were the staff and refresher staff in our hospital were recruited at the same time.A Chinese-made rTMS and a Runjie W J-1 ERPs instrument were used in the present experiment.N400 was elicited by congruent and noncongruent Chinese idioms.After rTMS treatment,N400,P300,and MMN characteristics were compared with those before treatment and NC group.Results:Compared with NC,the SZ patients exhibited delays in N400,P300,and MMN latency and decreased N400,P300,and MMN amplitudes in their frontal area (P < 0.05).After 25 rTMS treatments,N400 amplitudes in the frontal area (elicited by idioms with same phonic and different shape and meaning and with different phonic,shape,and meaning) were increased in the SZ patients (P < 0.05).However,there was no significant change in N400 before and after treatment with ShrTMS in SZ patients (P > 0.05).Amplitudes for MMN and target P300 also increased in SZ patients after rTMS treatment (P < 0.05).Conclusions:Based on our preliminary findings,we believe that the combined usage of N400,MMN,and P300 could be a valuable index and an electrophysiological reference in evaluating the effects ofrTMS treatment in SZ patients.

更多
广告
作者单位 Department of Psychiatry, Wenzhou Seventh People's Hospital, Wenzhou, Zhejiang 325005, China [1] Department of Electrophysiology, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China [2] Department of Function, Shanghai Jing'an District Mental Health Center, Shanghai 200030, China [3]
栏目名称 Original Articles
DOI 10.4103/0366-6999.223846
发布时间 2018-03-21
基金项目
This study was supported by a grant from the National Natural Science Foundation of China
提交
  • 浏览26
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2018年131卷3期

301-306页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷