• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Diagnostic Performance and Interobserver Consistency of the Prostate Imaging Reporting and Data System Version 2: A Study on Six Prostate Radiologists with Different Experiences from Half a Year to 17 Years

摘要Background:One of the main aims of the updated Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) is to diminish variation in the interpretation and reporting of prostate imaging,especially among readers with varied experience levels.This study aimed to retrospectively analyze diagnostic consistency and accuracy for prostate disease among six radiologists with different experience levels from a single center and to evaluate the diagnostic performance of PI-RADS v2 scores in the detection of clinically significant prostate cancer (PCa).Methods:From December 2014 to March 2016,84 PCa patients and 99 benign prostatic shyperplasia patients who underwent 3.0T multiparametric magnetic resonance imaging before biopsy were included in our study.All patients received evaluation according to the PI-RADS v2 scale (1-5 scores) from six blinded readers (with 6 months and 2,3,4,5,or 17 years of experience,respectively,the last reader was a reviewer/contributor for the PI-RADS v2).The correlation among the readers' scores and the Gleason score (GS) was determined with the Kendall test.Intra-/inter-observer agreement was evaluated using κ statistics,while receiver operating characteristic curve and area under the curve analyses were performed to evaluate the diagnostic performance of the scores.Results:Based on the PI-RADS v2,the median κ score and standard error among all possible pairs of readers were 0.506 and 0.043,respectively;the average correlation between the six readers' scores and the GS was positive,exhibiting weak-to-moderate strength (r =0.391,P =0.006).The AUC values of the six radiologists were 0.883,0.924,0.927,0.932,0.929,and 0.947,respectively Conclusion:The inter-reader agreement for the PI-RADS v2 among the six readers with different experience is weak to moderate.Different experience levels affect the interpretation of MRI images.

更多
广告
作者单位 Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China [1] Department of Library, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China [2]
栏目名称 Original Articles
DOI 10.4103/0366-6999.235872
发布时间 2018-09-19
基金项目
grants from the National Natural Science Foundation of China
提交
  • 浏览33
  • 下载16
中华医学杂志(英文版)

中华医学杂志(英文版)

2018年131卷14期

1666-1673页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷