Reliability of the measurement of glenoid bone defect in anterior shoulder instability

摘要Background:The size of the glenoid bone defect is an important index in selecting the appropriate treatment for anterior shoulder instability.However,the reliability of glenoid bone defect measurement is controversial.The purpose of the present study was to investigate the reliabilities of measurements of the glenoid bone defect on computed tomography and to explore the predisposing factors leading to inconsistency of these measurements.Methods:The study population comprised 69 consecutive patients who underwent surgery for recurrent anterior shoulder dislocation in Peking University Fourth School of Clinical Medicine from March 2016 to January 2017.The glenoid bone defect was measured by three surgeons on'self-confirmed'and'designated'3-D en-face views,and repeated after an interval of 3 months.Measurements included the ratio of the defect area to the best-fit circle area,and the ratio of the defect width to the diameter of the best-fit circle.The inter-and intra-observer reliabilities of the measurements were evaluated using intraclass correlation coefficients (ICCs).The maximum absolute inter-and intra-observer differences and the cumulative percentages of cases with inter-and intra-observer differences greater than these respective levels were calculated.Results:Almost all linear defect values were bigger than the areal defect values.The inter-observer ICCs for the areal defect were 0.557 and 0.513 in the'self-confirmed'group and 0.549 and 0.431 in the'designated'group.The inter-observer reliabilities for the linear defect were moderate or fair in the'self-confirmed'group (ICC =0.446,0.374) and'designated'group (ICC =0.402,0.327).The ICCs for intra-observer measurements were higher than those for inter-observer measurements.The respective maximum inter-and intra-observer absolute differences were 13.9% and 13.2% in the'self-confirmed'group,and 15.8% and 9.8% in the 'designated'group.Conclusions:The areal measurement of the glenoid bone defect is more reliable than the linear measurement.The reliability of the glenoid defect areal measurement is moderate or worse,suggesting that a more accurate and objective measurement method is needed in both en-face view and best-fit circle determination.Subjective factors affecting the glenoid bone loss measurement should be minimized.

更多
广告
作者单位 Department of Sports Medicine, Peking University Fourth School of Clinical Medicine, Beijing 100035, China [1]
栏目名称
DOI 10.1097/CM9.0000000000000481
发布时间 2019-12-31(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览10
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2019年132卷21期

2559-2564页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷