医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Loop changes after knee flexion-extension movement in a cadaveric anterior cruciate reconstruction model

Loop changes after knee flexion-extension movement in a cadaveric anterior cruciate reconstruction model

摘要Background::Recently, adjustable-loop devices (ALDs) have been widely used, and their reliability has always been the focus of attention. This study compared loop length changes under pull stress caused by flexion and extension of the cadaver knee between ALDs and fixed-loop devices (FLDs) in terms of femoral fixation after anterior cruciate ligament (ACL) reconstruction.Methods::ACL reconstruction in cadaveric knee joints was performed under arthroscopy with femoral suspension devices and tibial fixation by tying sutures on staples. The knee joint was repeatedly flexed and extended 30 times after fixation. According to the femoral fixation device used (Endobutton or Ultrabutton), the knee joints were divided into two groups: the ALD group (12 specimens) and the FLD group (ten specimens). The length of the loop before and after fixation was measured, and the loop length of the ALD group was re-measured 1 day after reconstruction.Results::There was no significant difference in the length of the loop between the two groups ( t = 0.579, P = 0.569). One day later, the loop length of the ALDs retracted by 0.29 ± 0.33 (0-1.1) mm, and there was no retraction in three specimens. Conclusion::There was no significant difference in the loop length under flexion and extension stress after ACL reconstruction between ALDs and FLDs.

更多

abstractsBackground::Recently, adjustable-loop devices (ALDs) have been widely used, and their reliability has always been the focus of attention. This study compared loop length changes under pull stress caused by flexion and extension of the cadaver knee between ALDs and fixed-loop devices (FLDs) in terms of femoral fixation after anterior cruciate ligament (ACL) reconstruction.Methods::ACL reconstruction in cadaveric knee joints was performed under arthroscopy with femoral suspension devices and tibial fixation by tying sutures on staples. The knee joint was repeatedly flexed and extended 30 times after fixation. According to the femoral fixation device used (Endobutton or Ultrabutton), the knee joints were divided into two groups: the ALD group (12 specimens) and the FLD group (ten specimens). The length of the loop before and after fixation was measured, and the loop length of the ALD group was re-measured 1 day after reconstruction.Results::There was no significant difference in the length of the loop between the two groups ( t = 0.579, P = 0.569). One day later, the loop length of the ALDs retracted by 0.29 ± 0.33 (0-1.1) mm, and there was no retraction in three specimens. Conclusion::There was no significant difference in the loop length under flexion and extension stress after ACL reconstruction between ALDs and FLDs.

More
广告
作者 Wang Jian [1] Yuan Fu-Zhen [1] Yu Jia-Kuo [1] 学术成果认领
作者单位 Institute of Sports Medicine, Peking University Third Hospital, Beijing Key Laboratory of Sports Injuries, Beijing 100191, China [1]
栏目名称
DOI 10.1097/CM9.0000000000000907
发布时间 2026-01-06(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览0
  • 下载0
中华医学杂志英文版

中华医学杂志英文版

2020年133卷14期

1676-1679页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷