• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Development and validation of a deep learning model to screen hypokalemia from electrocardiogram in emergency patients

Development and validation of a deep learning model to screen hypokalemia from electrocardiogram in emergency patients

摘要Background::A deep learning model (DLM) that enables non-invasive hypokalemia screening from an electrocardiogram (ECG) may improve the detection of this life-threatening condition. This study aimed to develop and evaluate the performance of a DLM for the detection of hypokalemia from the ECGs of emergency patients.Methods::We used a total of 9908 ECG data from emergency patients who were admitted at the Second Affiliated Hospital of Nanchang University, Jiangxi, China, from September 2017 to October 2020. The DLM was trained using 12 ECG leads (lead I, II, III, aVR, aVL, aVF, and V 1- 6) to detect patients with serum potassium concentrations <3.5 mmol/L and was validated using retrospective data from the Jiangling branch of the Second Affiliated Hospital of Nanchang University. The blood draw was completed within 10 min before and after the ECG examination, and there was no new or ongoing infusion during this period. Results::We used 6904 ECGs and 1726 ECGs as development and internal validation data sets, respectively. In addition, 1278 ECGs from the Jiangling branch of the Second Affiliated Hospital of Nanchang University were used as external validation data sets. Using 12 ECG leads (leads I, II, III, aVR, aVL, aVF, and V 1- 6), the area under the receiver operating characteristic curve (AUC) of the DLM was 0.80 (95% confidence interval [CI]: 0.77-0.82) for the internal validation data set. Using an optimal operating point yielded a sensitivity of 71.4% and a specificity of 77.1%. Using the same 12 ECG leads, the external validation data set resulted in an AUC for the DLM of 0.77 (95% CI: 0.75-0.79). Using an optimal operating point yielded a sensitivity of 70.0% and a specificity of 69.1%. Conclusions::In this study, using 12 ECG leads, a DLM detected hypokalemia in emergency patients with an AUC of 0.77 to 0.80. Artificial intelligence could be used to analyze an ECG to quickly screen for hypokalemia.

更多

abstractsBackground::A deep learning model (DLM) that enables non-invasive hypokalemia screening from an electrocardiogram (ECG) may improve the detection of this life-threatening condition. This study aimed to develop and evaluate the performance of a DLM for the detection of hypokalemia from the ECGs of emergency patients.Methods::We used a total of 9908 ECG data from emergency patients who were admitted at the Second Affiliated Hospital of Nanchang University, Jiangxi, China, from September 2017 to October 2020. The DLM was trained using 12 ECG leads (lead I, II, III, aVR, aVL, aVF, and V 1- 6) to detect patients with serum potassium concentrations <3.5 mmol/L and was validated using retrospective data from the Jiangling branch of the Second Affiliated Hospital of Nanchang University. The blood draw was completed within 10 min before and after the ECG examination, and there was no new or ongoing infusion during this period. Results::We used 6904 ECGs and 1726 ECGs as development and internal validation data sets, respectively. In addition, 1278 ECGs from the Jiangling branch of the Second Affiliated Hospital of Nanchang University were used as external validation data sets. Using 12 ECG leads (leads I, II, III, aVR, aVL, aVF, and V 1- 6), the area under the receiver operating characteristic curve (AUC) of the DLM was 0.80 (95% confidence interval [CI]: 0.77-0.82) for the internal validation data set. Using an optimal operating point yielded a sensitivity of 71.4% and a specificity of 77.1%. Using the same 12 ECG leads, the external validation data set resulted in an AUC for the DLM of 0.77 (95% CI: 0.75-0.79). Using an optimal operating point yielded a sensitivity of 70.0% and a specificity of 69.1%. Conclusions::In this study, using 12 ECG leads, a DLM detected hypokalemia in emergency patients with an AUC of 0.77 to 0.80. Artificial intelligence could be used to analyze an ECG to quickly screen for hypokalemia.

More
广告
作者 Wang Chen-Xi [1] Zhang Yi-Chu [1] Kong Qi-Lin [1] Wu Zu-Xiang [1] Yang Ping-Ping [1] Zhu Cai-Hua [1] Chen Shou-Lin [2] Wu Tao [1] Wu Qing-Hua [1] Chen Qi [1] 学术成果认领
作者单位 Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Nanchang, Jiangxi 330006, China [1] Department of Anesthesiology, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Nanchang, Jiangxi 330006, China [2]
栏目名称 Original Article
DOI 10.1097/CM9.0000000000001650
发布时间 2025-03-04
基金项目
National Natural Science Foundation of China
  • 浏览57
  • 下载9
中华医学杂志英文版

中华医学杂志英文版

2021年134卷19期

2333-2339页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷