• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction for bone sarcomas: long-term outcomes

Computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction for bone sarcomas: long-term outcomes

摘要Background::Computed tomography (CT) and magnetic resonance imaging (MRI) data can be fused to identify the tumor boundaries. This enables surgeons to set close but tumor-free surgical margins and excise the tumor more precisely. This study aimed to report our experience in performing computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction to treat bone sarcoma in the diaphysis and metaphysis of the femur and tibia.Methods::Between September 2008 and December 2015, 24 patients with bone sarcomas underwent surgical resection and joint-sparing reconstruction under image-guided computer navigation. The cohort comprised 16 males and eight females with a median age of 19.5 years (range: 12-48 years). The tumor location was the femoral diaphysis in three patients, distal femur in 19, and proximal tibia in two. The tumors were osteosarcoma ( n = 15), chondrosarcoma ( n = 3), Ewing sarcoma ( n = 3), and other sarcomas ( n = 3). We created a pre-operative plan for each patient using navigation system software and performed navigation-aided resection before reconstructing the defect with a custom-made prosthesis with extracortical plate fixation. Results::Pathological examination verified that all resected specimens had appropriate surgical margins. The median distance from the tumor resection margin to the joint was 30 mm (range: 13-80 mm). The median follow-up duration was 62.5 months (range: 24-134 months). Of the 24 patients, 21 remain disease free, one is alive with disease, and two died of the disease. One patient developed local recurrence. Complications requiring additional surgical procedures occurred in six patients, including one with wound hematoma, one with delayed wound healing, one with superficial infection, one with deep infection, and two with mechanical failure of the prosthesis. The mean Musculoskeletal Tumor Society score at the final follow-up was 91% (range: 80%-100%). The 5- and 10-year implant survival rates were 91.3% and 79.9%, respectively.Conclusions::Computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction with extracortical plate fixation is a reliable surgical treatment option for bone sarcoma in the diaphysis and metaphysis of the femur and tibia.

更多

abstractsBackground::Computed tomography (CT) and magnetic resonance imaging (MRI) data can be fused to identify the tumor boundaries. This enables surgeons to set close but tumor-free surgical margins and excise the tumor more precisely. This study aimed to report our experience in performing computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction to treat bone sarcoma in the diaphysis and metaphysis of the femur and tibia.Methods::Between September 2008 and December 2015, 24 patients with bone sarcomas underwent surgical resection and joint-sparing reconstruction under image-guided computer navigation. The cohort comprised 16 males and eight females with a median age of 19.5 years (range: 12-48 years). The tumor location was the femoral diaphysis in three patients, distal femur in 19, and proximal tibia in two. The tumors were osteosarcoma ( n = 15), chondrosarcoma ( n = 3), Ewing sarcoma ( n = 3), and other sarcomas ( n = 3). We created a pre-operative plan for each patient using navigation system software and performed navigation-aided resection before reconstructing the defect with a custom-made prosthesis with extracortical plate fixation. Results::Pathological examination verified that all resected specimens had appropriate surgical margins. The median distance from the tumor resection margin to the joint was 30 mm (range: 13-80 mm). The median follow-up duration was 62.5 months (range: 24-134 months). Of the 24 patients, 21 remain disease free, one is alive with disease, and two died of the disease. One patient developed local recurrence. Complications requiring additional surgical procedures occurred in six patients, including one with wound hematoma, one with delayed wound healing, one with superficial infection, one with deep infection, and two with mechanical failure of the prosthesis. The mean Musculoskeletal Tumor Society score at the final follow-up was 91% (range: 80%-100%). The 5- and 10-year implant survival rates were 91.3% and 79.9%, respectively.Conclusions::Computer navigation-aided joint-preserving resection and custom-made endoprosthesis reconstruction with extracortical plate fixation is a reliable surgical treatment option for bone sarcoma in the diaphysis and metaphysis of the femur and tibia.

More
广告
作者 Li-Hui Xu [1] Qing Zhang [1] Hai-Tao Zhao [1] Feng Yu [1] Xiao-Hui Niu [1] 学术成果认领
作者单位 Department of Orthopedic Oncology Surgery, Beijing Ji Shui Tan Hospital, Peking University, Beijing 100035, China [1]
栏目名称
DOI 10.1097/CM9.0000000000001750
发布时间 2025-04-22
  • 浏览59
  • 下载0
中华医学杂志英文版

中华医学杂志英文版

2021年134卷21期

2597-2602页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷