Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

摘要Background::It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed.Methods::Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion.Results::Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL ( P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086). Conclusion::In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.Trial registration::ClinicalTrials.gov, NCT04515511

更多

abstractsBackground::It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed.Methods::Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion.Results::Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL ( P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086). Conclusion::In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.Trial registration::ClinicalTrials.gov, NCT04515511

More
广告
作者 Yang Ting [1] Weng Li [1] Jiang Wei [1] Li Shan [1] Du Bin [1] 学术成果认领
作者单位 Medical Intensive Care Unit, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China [1]
栏目名称 Original Article
DOI 10.1097/CM9.0000000000001919
发布时间 2025-02-25
基金项目
The study was supported by grants from the Ministry of Science and Technology of People Republic of China Beijing Municipal Science and technology commission
  • 浏览43
  • 下载0
中华医学杂志英文版

中华医学杂志英文版

2022年135卷6期

672-680页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷