医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

双源CT痛风识别技术在检测尿酸盐沉积中的应用

The value of using dual-energy CT in the detection of monosodium urate crystals in patients with gout

摘要目的 评价双能量CT(DECT)痛风识别技术在检测痛风患者尿酸盐结晶沉积中的应用.方法 回顾性分析108例近2周发作过单关节肿和(或)痛患者的患肢关节双能量CT扫描资料,其中符合美国风湿病学会(ACR) 1977年分类标准的痛风患者95例,非痛风组13例.95例痛风患者双能量CT扫描后得到的双能0.3比例融合图像组作为常规组;所获得的80 kV及140 kV图像输入痛风识别软件,后处理获得的伪彩图像组作为后处理组.观察常规组与后处理组发现的尿酸盐结晶,并采用x2检验比较;比较两组发现尿酸盐结晶的敏感度和准确率,并采用x2检验进行比较.结果 常规组中有51例患者能显示软组织内尿酸盐结晶,显示病灶的部位共298处;13例非痛风患者中有2例显示高密度结晶;常规组发现尿酸盐结晶的敏感度为53.7%,特异度为84.6%,准确率为57.4%.后处理组中69例患者发现散在的绿色的尿酸盐结晶,显示病灶的部位共401处;13例非痛风患者均未显示绿色的尿酸盐结晶;后处理组发现尿酸盐结晶的敏感度为72.6%,特异性为100.0%,准确率为75.9%.两组发现尿酸盐结晶的病灶数差异有统计学意义(x2=5.193,P<0.05),发现尿酸盐结晶的敏感度和准确率差异也有统计学意义(x2值分别为7.329和8.333,P值均<0.05).结论 DECT痛风识别技术能发现更多部位、更小体积的尿酸盐结晶,在痛风早期诊断、监测治疗疗效中有潜能.

更多

abstractsObjective To evaluate the clinical value of dual-energy CT in the detection of monosodium urate crystals in patients with gout.Methods One hundred and eight patients who experienced unilateral arthrocele and (or) joint pain in the past two weeks were enrolled into our study.DECT were performed for the upper or lower extremity.Ninety-five patients were enrolled into the gout study group based on the American rheumatism association (ACR) classification standard;The 0.3 linear blended images group were regarded as conventional CT group,DE (80 kV and 140 kV) datasets were reconstructed via gout-recognition software,the pseudo-color images group as the postprocessed group.Imagings were reviewed independently by two senior radiologists.Chi-square test were used for statistical analysis with the SPSS 13.0software.Results In the conventional CT group,DECT scans revealed a total of 298 areas of urate deposition in 51 patients;The sensitivity,specificity,and accuracy were 53.7%,84.6%,and 57.4%.In the postprocessed group,401 areas of green urate deposition were detected in 69 patients,the sensitivity,specificity,and accuracy were 72.6%,100.0%,75.9% respectively,the differences had statistical significance (x2 =7.329 and 8.333,P < 0.05).Conclusions DECT gout recognition technology can detect smaller amount of monosodium urate in the other parts of the body,with a great potential in early diagnosis and treatment monitoring of patients with gout.

More
广告
DOI 10.3760/cma.j.issn.1005-1201.2012.12.011
发布时间 2013-02-22(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览617
  • 下载424
中华放射学杂志

中华放射学杂志

2012年46卷12期

1101-1104页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷