海上100 m氦氧饱和-108 m巡潜潜水员的机体负荷监测及保障建议

Suggestions on monitoring and support for divers’ body load during 100 m-108 m heliox saturation diving at sea

摘要目的:对海上大深度氦氧饱和潜水高气压暴露过程中潜水员的机体负荷进行监测,为保障潜水员的健康安全提供参考。方法:采用心率与自我运动强度感觉量表(RPE)相结合的方法监测潜水员的机体负荷状态,并对结果进行分析。结果:4名潜水员整体心率平稳,减压第3天6∶30(63 m)1号潜水员出现极低心率(43次/min),3号潜水员心率为53次/min。潜水员饱和暴露及减压各阶段心率与入舱前比较差异均无统计学意义( P>0.05)。潜水员整体RPE评分为6~16分,整体变化趋势与高气压暴露过程相吻合,100 m稳压至巡潜结束阶段潜水员的机体负荷最大,其余阶段负荷较小。RPE评分在入舱前略高于加压阶段,巡潜阶段达到高峰,减压阶段处于平稳状态,第2钟潜水员巡潜结束时的RPE评分显著高于入舱前( t=-4.700, P=0.018)。 结论:高压条件下,对潜水员进行机体负荷的监测对保障作业安全具有重要的意义。心率与RPE的联合监测能更精准地反映机体负荷,有助于更好地保障潜水作业安全。

更多

abstractsObjective:To monitor and analyze the divers’ body load during hyperbaric exposure in deep heliox saturation diving at sea, so as to provide reference for safeguarding the safety and health of divers.Methods:The heart rate and rating of perceived exertion (RPE) of the divers were taken to monitor their body loads and the results were analyzed.Results:The heart rates of the four divers were stable. At 6: 30 (63 m) on the third day of decompression, diver 1 had a very low heart rate of 43 beats/min and diver 3 had a heart rate of 53 beats/min. There was no statistically significant difference in the mean heart rates of divers during saturation exposure and each time point of decompression with those before entering the cabin. The overall RPE results of divers ranged from 6 to 16 points, and the overall trend of development was consistent with the pressure change; the highest load was shown in the stage from 100 m stable pressure to the end of excursion diving, while the loads in other stages were relatively small. The mean value of RPE before entering the cabin was slightly higher than that in the pressurized stage, and it reached the peak in the excursion diving stage and then remained stable in the decompression stage. The RPE results of divers in the second diving bell at the end of excursion diving stage were significantly higher than those before entering the cabin ( t=-4.700, P=0.018). Conclusion:It is of important value to guarantee the operation safety by monitoring the divers’ body loads under high pressure. The combination of monitoring heart rate and RPE results can accurately reflect the body load and is conducive to the safety of diving operation.

More
广告
作者 王义普 王炀炀 朱礼健 张庆元 梁厚勇 杨元青 吉梦瑶 周全 学术成果认领
DOI 10.3760/cma.j.cn311847-20210305-00073
发布时间 2025-04-22
  • 浏览59
  • 下载0
中华航海医学与高气压医学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷